TC36ST_NGST04D_
091014-16
10
Date:
______________________
By / Par:
___________________
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
10.0 in/wc / 10.0 po/c.e.
(2.49 kPa)
2.50 mm
Max.: 61,000Btu (17.8kw)
Min.: 47,000Btu (13.7kw)
081014 6-TC36ST_D 5052.5206D
This kit for use with model: / TC36STNG03.D
Pour utilise avec du modèle: / TC36STNG04.D
TC42
Series D
This appliance was converted
t o P R O PA N E G A S w i t h
this kit on this date by the
organization which accepts
the responsibility that this
conversion has been properly
made. / Cet appariel etair
converter au gaz LP par l’emploi
de la trousse de conversion par
une organization qui accepte
la responsibilité pour une
installation en bon état.
HOLE
5. With a 7/16” wrench loosen the pilot head
on the pilot assembly using a wrench to
hold the bracket steady. (Fig. #19)
6.
Slide the pilot adjustment band over and
ensure that the hole in the orifice band
is showing.
Fig. #20a shows NG position
Fig. #20b shows LP position).
Re-attach the pilot assembly.
7.
Remove the access panel, 10 screws,
and set aside.
8.
Fill in the date and the name of the
person who performed the conversion
in the white area on the conversion
label. Peel off the protective backing and
apply the conversion label directly over
the gas specifications on the rating label.
9. Attach the access panel to the side of
the firebox with the previously removed
screws.
Note: Gasket must be installed with
access panel.
Fig #19
Fig #20a
NG POSITION
LP POSITION
Fig #20b
ADD NAME
ADD DATE
For complete valve installation instructions, refer to the
instruction book included in the SIT conversion kit.