9
TC30.NG04C 180411-20
WARNING
This conversion kit
shall be installed by a
qualifi ed service agency
in accordance with the
manufacturer's instructions
and all applicable codes
and requirements of
the authority having
jurisdiction.
If the information in these
instructions is not followed
exactly, a fi re, explosion
or production of carbon
monoxide may result
causing property damage,
personal injury or loss of
life.
The qualifi ed service
agency is responsible for
the proper installation of
this kit.
The installation is not
proper and complete
until the operation of the
converted appliance is
checked as specifi ed in the
manufacturer's instructions
supplied with the kit.
If the unit is to be used on propane
conver t as follows using the
components supplied with this
burner:
CAUTION
The gas supply and electrical power
shall be shut off before proceeding
with the conversion.
Note:
Factory supplied components must be used
to ensure correct input.
After conversion confi rm proper manifold
pressure.
1.
Remove the 2 front screws holding the
burner tray in place.
(Fig.
#16)
2.
Gently lift up the burner tray while
sliding to the left to disengage the
burner tube from the orifi ce. Then tip
back to expose the orifi ce.
3.
Using a 1/2” wrench, undo the
natu ral gas burner orifi ce,
(marked
#32
). Apply a small amount
of pipe joint compound to the threads
of the propane burner orifi ce
(marked
#48
) to ensure a good seal,
before screwing it into the fi tting.
Loosen the primary air shutter screw,
open
shutter
half way
and re-tighten.
(Fig.
#17)
4.
Remove the 2 screws holding the
pilot assembly in place with a stubby
screwdriver.
(Fig
#18)
The burner assembly must
be removed from the unit if
previously installed.
Fig #16
Fig #17
Fig #18
Propane Conversion
For use with model:
Pour utilise avec du modèle:
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
11.0 in/wc / 11.0 po/c.e.
(.95 kPa)
# 48 (1.93 mm)
Max.: 35,000 (10.3)
Min.: 27,000 (7.91)
080411 6-TC30 5052.52085
Date:
______________________
By / Par:
___________________
This appliance was converted
to PROPANE GAS with this kit
on this date by the organiza-
tion which accepts the respon-
sibility that this conversion
has been properly made. / Cet
appariel etair converter au gaz
LP par l’emploi de la trousse
de conversion par une organi-
zation qui accepte la responsi-
bilité pour une installation en
bon état.
TC30
Series C
MAIN BURNER
(#48) ORIFICE (5021.3407)
MINIMUM RATE SCREW (5005.011)
Содержание TC30.NG04C
Страница 17: ...17 TC30 NG04C 180411 20 ...
Страница 18: ...18 TC30 NG04C 180411 20 ...
Страница 19: ...19 TC30 NG04C 180411 20 LP ...