- 10 -
tousek
/ E_TURN-310UF_43000203 / 19. 03. 2013
8
8a
8b
8a
9
7a
7b
4
7
7a
4
2h. Putting on the housing cover
Installation
In case of a defect or power failure the operator can be
emergency released as follows:
•
Turn off power supply!
• Open plastic cap at the emergency release mechanism
(7a).
• Insert emergency release lever
(7b)
as shown in the
drawing and turn it right till the gate bearing
(7)
is released
of the gate driver (4). Keep this position and release the
gate manually.
• To restore motor operation turn the gate until you can hear
that it has re-engaged.
• Put on the plastic cap again.
Note
•
Installation, connection, taking into operation and
maintenance may only be carried out by qualified
professionals and with regard to this manual.
3. Note for the user - Emergency release (e.g. at power failure)
TURN 310 UF
• After finishing the installation- and adjustment works put
the housing cover
(8)
on the underfloor housing and fix it
with 2 screws
(8a)
in the intakes
(8b)
at the sides of the
housing.
• Finally put on the plastic cover
(9).
Note
•
Before closing the housing please note the
suggestion on page 5.