tousek
/ EN_ST-64_02 / 25. 03. 2020
- 15 -
Safety sensing edges
Safety
•
Connection and detailed information of radio transmission system TX 310 see according manual.
G
main safety edge 1
(terminals KL1 50/52)
Safety
active:
to be selected if the contact strip (8,2kOhm) of main safety sensing edge 1 should be evaluated.
not active:
to be selected if the contact strip of main safety sensing edge 1 should
not
be evaluated
radio edge TX310:
to be selected if safety sensing edge (8,2kΩ) of main entrance edge 1 should be evaluated
with
the radio transmission system TX 310
.
G
main safety edge 2
(terminals KL1 50/53)
Safety
active:
to be selected if the contact strip (8,2kOhm) of main safety sensing edge 2 should be evaluated.
not active:
to be selected if the contact strip of main safety sensing edge 2 should
not
be evaluated
radio edge TX310:
to be selected if safety sensing edge (8,2kΩ) of main entrance edge 2 should be evaluated
with
the radio transmission system TX 310
.
Safety sensing edges (main closing edge 1 + 2)
•
OBSTACLE DETECTION:
when a contact strip/safety edge is triggered/activated then a change of direction is
effected for 1 second. Then the gate stops.
• The activation of the safety sensing edges is made in menu
„Safety / main closing edge 1“
(term. 50/52) and
„Safety / main closing edge 2“
(term. 50/53)
• If in the menu item
„operating logic / closing edge“
(
page
18) one of the modes
„left / right“
or
„inside
/ outside“
is selected - this results in the wiring of the
safety contact edges to make with each other and the
connection to the control terminals.
Safety sensing edges in mode
„left/right“
, that should react on an obstacle at the left (right) leaf, have to
be connected (serially) to the connection clamps of the main closing edge 1 (2) .
Safety sensing edges in mode
„inside/outside“
, which should react
on an obstacle at the inner (outer)
side of the leaf,
be connected (serially) to the connection clamps of the main closing edge 1 (2)
Example: W
8,2kΩ final resistance
E
final edge
D
passage edge
S
to the control board
When connecting one safety edge a final edge
(E)
has to be used.
E
W
D
D
S
50
52
50
53
main closing edge 1
main closing edge 2
Important
•
After giving the impulse to program the end positions, no other impulse must be given. Also the safety devices
mustn´t be triggered. This would lead to an interruption of the programming process.
•
Therefore, the mechanical stops must be set so that the existing contact strips cannot be triggered.
main closing edge 2
(right leaf or outside)
main closing edge 1
(right leaf or outside)
8,2kΩ
8,2kΩ
53
52
50
KL1