ELECTRICAL SAFETY

BD4603

5

WIRING DIAGRAM

The machine must be grounded.

 MM491G

In the event of a malfunction or breakdown, 

grounding provides a path of least resistance 

for electric current to reduce the risk of ele-

ctric shock. This tool is equipped with an electric 

cord having an equipment-grounding conductor 

and a grounding plug. The plug must be plugged

into a matching outlet that is properly installed 

and grounded in accordance with all local codes 

and ordinances.
Do not modify the plug provided. If it will not 

fit the outlet, have the proper outlet installed 

by a qualified electrician.
Improper connection of the equipment-grou

nding conductor can result in a risk of electric

shock. The conductor, with insulation having 

an outer surface that is green with or without

yellow stripes, is the equipment-grounding 

conductor. If repair or replacement of the ele-

ctric cord or plug is necessary, do not connect

the equipment-grounding conductor to a live

terminal.
Check with a qualified electrician or service 

personnel if the grounding instructions are 

not completely understood, or if in doubt as 

to whether the tool is properly grounded.
Use only three wire extension cords that have 

three-prong grounding plugs and three-pole 

receptacles that accept the tool’s plug.
Repair or replace a damaged or worn cord 

immediately.
This tool is intended for use on a circuit that 

has an outlet that looks the one illustrated in 

Figure A below. The tool has a grounding plug 

that looks like the grounding plug as illustra-

ted in Figure A below. A temporary adapter,

which locks like the adapter as illustrated in

Figure B below, may be used to connect this 

plug to a two-pole receptacle, as shown in Figure

B if a properly grounded outlet is not available.

The temporary adapter should only be used 

until a properly grounded outlet can be installed 

by a qualified electrician. The green colored 

rigid ear or tab, extending from the adapter, 

must be connected to a permanent ground 

such as a properly grounded outlet box.

* Canadian electrical codes require extension 

   cords to be certified SJT type or better.

** Use of an adapter in Canada is not acceptable.

Replacement of the power supply cable should 

only be done by a qualified electrician.

Fig

.

 C

Содержание MM491G

Страница 1: ...IMPORTANT For your own safety read and follow all of the Safety Guidelines and Operating Instructions before operating this product MM491G 4 X 36 BELT AND 6 DISC SANDER INSTRUCTION MANUAL...

Страница 2: ......

Страница 3: ...Y PARTS DIAGRAN 7 ASSEMBLY MOUNTING 9 OPERATION 11 MAINTENANCE 12 TROUBLESHOOTING GUIDE 13 EXPLONED VIEW 14 PARTS LIST 17 WARRANTY 18 ELECTRICAL SAFETY 5 SPECIFICATIONS 2 Motor 120 VAC 4 3A 60 Hz 1 2...

Страница 4: ...WORK AREA CLEAN Cluttered areas and benches invite accidents ALWAYS KEEP VISITORS AWAY FROM RUNNING MACHINES All visitors should be kept a safe distance from the work area ALWAYS MAKE THE WORKSHOP CH...

Страница 5: ...sition prior to plugging in the machine 11 Always make sure the power switch is in the OFF position when doing any assembly or setup operation 12 Always wear a dust mask and use adequate dust collecti...

Страница 6: ...rsonnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Use only three wire extension cords that have three prong grounding plugs...

Страница 7: ...PACKAGE CONTENTS No Description Qty 1 2 3 4 5 6 7 1 1 1 1 1 2 1 Sander Body Miter Gauge Work Table Miter Gauge Knob Big Flat Washer Hex Socket Round Head Screw Limited plate MM491G 1 2 3 4 5 6 7 Figur...

Страница 8: ...BD4603 7 KEY PARTS DIAGRAN Miter Gauge MM491G Work Table Sander Belt Sander Disc Belt Tension Knob Switch Limited plate Belt Adjustable Knob...

Страница 9: ...sanding disc over plate When aligned press sandpaper disc firmly onto backing disc 3 Position disc guard 6 onto lower portion of sanding disc so that the mounting holes align 4 Using a Phillips screwd...

Страница 10: ...Place washer 32 on knob 34 shaft and insert through slot into threaded holes in base 6 Loosen the three hex screws 31 and adjust table so that there is a maximum of 1 5mm 1 16 space between the sandin...

Страница 11: ...lling and Adjusting the Sanding Belt 1 Turn power switch to the OFF position and disconnect power cord from the main elec tricity supply 2 Move tension lever 66 to the right to rel ease the sanding be...

Страница 12: ...BD4603 11 MM491G OPERATIONS...

Страница 13: ...them 3 Place drive belt around drive pulley 71 then drive pulley 78 4 Tighten the three screws slightly 5 Adjust tension of drive belt by placing a standard screwdriver in the adjusting hole by pushi...

Страница 14: ...electrician carry out repair Timing belt too tight Applying too much pres sure on workpiece Wood burns while sanding Sander does not operate Motor slows when sanding Sanding disc or belt is loaded wit...

Страница 15: ...14 EXPLODED VIEW MM491G...

Страница 16: ...1 Wire Connection Box 1 12 Phillips Screw M5X8 M5X8 7 13 Phillips Screw M5X25 Spring Washer M5X25 3 14 Belt Tension Knob 1 15 Screw Bushing 1 16 Phillips Screw M5X16 Toothed Lock Washer Big Flat Washe...

Страница 17: ...7 1 40 Tension Spring 1 41 Bushing 2 42 Belt Tension Support 1 43 Spring Retaining Ring for Shaft D12 D12 2 44 Bearing 5 45 Idler Drum 1 46 Idler Shaft 1 47 Phillips Screw 3 5 9 5 3 5 9 5 4 48 Sw itch...

Страница 18: ...XL 1 71 Driven Pulley 1 72 Phillips Screw M6X25 Flat Washer spring w asher M6x25 3 73 Hex Socket Round Head Screw M8X25 M8X25 1 74 Cog Belt Guard Cover 1 75 Square Nut M8 M8 1 76 Cord Plug 1 77 Tube 8...

Страница 19: ...Having Problems Give us a chance to help you before returning this product Email After the phone 844 866 5687 ONE YEAR LIMITED WARRANTY info toolots com PARTS LIST 18 EXPLODED VIEW MM491G WARRANTY...

Страница 20: ......

Отзывы: