Inspection

5

6

3

1

1

Filter

Open/shut 
Tool

Confirm the following items after installation.

Confirm there is no water leakage.

Check for leakage

 

Confirm the pipe is not  
rusted or broken, then  
install it again.

Water leaks from A-D

Confirm that the gasket  
has been installed, then  
fasten the nut.

Water leaks from C

Water leaks from B

Upper 
Installation 
fitting

Installation 
Legs

2

Cap nut

Lower 
installation 
fitting

A 

B 

C 

D

Is the installation fitting stall?

  − 

4

Does the cap nut get loose?

Is the installation leg  
stable?

  − 

3

Is the filter blocked?

2.See  Clean the filter  
 

Open the stop valve completely

Is the stop valve open?

Confirm there is no shaking.

Confirm the shaking

If the flow is small or the temperature is 
inappropriate, check the following item.

Check the flow and temp.

※The Operation Manual attached to the delivery must be provided to the customer.

This is Printed on Recycled Paper.

1

2

3

5

6

6

Stop 
valve 
(cold)

Stop 
valve 
(hot)

Check if the O ring is abnormal, 
if it is shifted to one side during 
installation, 
you should install it again.

Refer to  Install the 
Installation Fitting  

Refer to  Install the 
Installation legs  

Does showerhead 
have movement or looseness?

  − 

5

4

Refer to  Install the 
showerhead  

4

Showerhead

6/6