INSTALLATION & INSTRUCTION MANUAL FOR BATH & SHOWER SET
DGM301CFN/ DGM301CFNS
Quantity
Part name
Shower faucet
Shower head
1 set
1 pc
Part name
Hanger
Hose
150±20
150
Wall line
22.5
Hot
Cold
Length
1500
Open
Red
Blue
Close
2-Ø6x30
Connector
● Always wipe chrome plated area with dry soft cloth, and sometimes wipe it
with cloth soaked in mild soap.
● If the dirt is difficult to clean, use neutral soap.
● In case of not using for a long time, sometimes spray to avoid rusty
ATTENTION
● Do not use abrasive cleaning material or tool such as detergents containing
hydrochloric acids, thinner, polishing powder, and nylon brush.
● Do not remove the cartridge, otherwise the shower will be damaged.
Unit: mm
OPERATING CONDITIONS
1. Water supply pressure: 0.05 ~ 0.75 MPa.
2. Ensure that supply water is clean (no sand, dirt, water soluble but
may precipitate substances such as Ca(HCO3)2,...).
3. Ambient temperature must be above 0oC.
4. The temperature of hot supply water from must not be exceed 85oC.
INSTALLATION GUIDE
BEFORE THE INSTALLATION
1. The hot water supply must be on the left, cold one on the right side.
2. The distance between hot water supply and cold water supply inlets
must be 150±20mm. Otherwise, you can not install the shower faucet.
3. In case the water supply pressure is greater than 0.75MPa, please use
the pressure relief valve (available in the market) to lower pressure
down to 0.2~0.3MPa. To have a refreshing feeling while using, set
water pressure of 0.2~0.3MPa.
4. In case the water supply pressure is too low (less than 0.05MPa), you must
increase the pressure by using pump or increase the water tank height.
5. For the hot water supply pipe from the water heater, to minimize the
loss, you should better lay the water supply pipe you should better lay
the water supply pipe with the shortest length. Wrap heat insulating
material or use heat insulating pipe.
6. Open valve to rinse sand, dirt, ect in the water suply inlets before installing.
HOW TO INSTALL
4. Install the hanger
Install installation holes then install hanger.
Expansion
Drill
2-Ø6 hole
Srew Hanger
5. Connect the shower
Connect the shower head to the hose
as the picture on the right side.
Connect the hose to the faucet.
Attention: Must install with packing.
6. Turn the cover to close to the wall
Packing
Nut
(4. Is the nut loose? Is the
packing scratched or
dirt)
Diverter
Packing
(5. Are the O-ring and
packing in the bottom
scratched or dirt?)
Diverter base
Spray head
(6. Is the packing scratched or dirt?
7. Is the filter clogged?)
Packing
(125)
2. Install the cover
Install the cover to con-
nector temporarily.
3. Install the shower faucet
Install the shower faucet to the
connector, you can adjust the
connector to install the faucet.
TROUBLESHOOTING
Trouble
Spray weak
Leak
Check point
7
2, 3, 4, 5, 6
Lever
Cartridge cover
Cartridge
(3. Are the O-ring
and packing in the
bottom scratched or
dirt?)
Cover
Trouble
Lever or esukatchon vibrates
Trouble of diverter
Screw
(1. Is it ightened?)
Red-blue eye
Nut
(2. Is it ightened?)
Diverter button
Check point
1, 2
5
Quantity
1pc
1 pc
Part name
Cover
Connector
Quantity
2 pcs
2 pcs
1. Install the connector
Use the seal tape, warp the thread of G1/2 of the connectors then
connect to the water supply inlets (hot and could).
Attention
● Inlets must indent from wall line 0~6mm, otherwise, you can not cover inlets.
● Adjust so that height of hot and cold connectors are equal, plane of
two connector ends is parallel with the wall line, distance between
connectors is 150mm.
Hot water
supply inlet
Cold water
supply inlet
Must be parallel
with wall line
HOW TO USE
● Pull the lever up to open, push the lever down to close.
● Turn left the lever to get hotter water, right to get colder water.
● Pull the diverter button up to get shower spray, push the diverter button down
to get faucet spray.
ATTENTION IN USING
● Use your hands to check water temperature before using to avoid burns.
● Do not touch the faucet’s left side or connector on the left to avoid burns.
● To avoid burn, set the water heater temperature not over than 60oC.
MAINTENANCE
45°
45°
25°
40°
15°
G1/2
Ø65
Max 1150
2.2 5
TOTO
BILL OF PARTICULAR
USER GUIDE
SPECIFICATIONS
TOTO
150
150±20
0~6mm
0IMI73201/04