background image

 

 

 

 

 

 

5. Commencement of operation 

Use of lifting devices  

The apparatus should be lifted with a fork-lift truck or lifted  provided  with slings.  For lifting points the 
tube supports or other sections may not be used. 
 

Putting up of the Apparatus 

With putting up of the apparatus the following points should be observed: 

  The  apparatus  should  not  be  exposed  to  weather.  Only  special  types  resistable  to  weather  are 

appropriate for the open air.  

  Take  care,  that  the  place  intended  for  putting  up  is  flat and  can  handle  the  working  weight  of  the 

dehumidifier. A foundation is not required. 

  Before the operation side and the inspection lids, especially near the rotor, at least apply a width of 

the apparatus free space for repair and maintenance work.  

A)  Air dehumidifiers are not meant for putting up to suck up moistures, 

f.i.filled tanks or tubs, flooded surfaces etc. 

B)  Operation is only allowed in and/or with explosion sensitive atmosphere 

for apparatuses which are in accordance with guideline 94/9/EG (Atex 
95). The operator is obliged to check appropriate deployment of the 
dehumidifier, according guideline 1999/92/EG (Atex 137)! 

 

Connection of the apparatus 

A)  Way of putting up inside the room to be dehumidified : 

 

The apparatus works in environment air, the regeneration 

spent air 

is to be carried to the outside. 

This part is to be compensated by fresh air. 

B)  Way of putting uo outside the room to be dehumidified : 

 

The  apparatus  can  be  connected  in  regenerated  air  or  fan  air  operation.  Herewith  a  connection 
should  be  put  up  for  the  dried  air  to  the  dehumidifying  room.  Here  also  applies  that  with 
regenerated air the regenerated part is to be compensated with fresh air.  

 

The apparatus has been constructed in such a way, that the air channels as well as the electrical 
connections can be installed simply. Mind the following indications  : 

 

The piping system has to be installed on the present static pressing of  the fans. To keep loss in 
pressure  as  low  as  possible,  the  air  hoses  should  be  fitted  as  straight-lined  as  possible  and  as 
short as possible. 

 

 The pipe for the regeneration used air (damp air) should be fitted with a small fall (min. -1,5%), so 
that    possible  resulting  condensation  does  not  flow  back  into  the  apparatus  or  obstructs  the  air 
flow.  To  prevent  situations  below  dew  point  definitely,  the  exhaust  pipe  should  be  blocked  off 
sufficiently.  In case  a  rising  air  pipe  is  unavoidable,  a  lowest  point  with  draining  should  be  made 
intentionally (f.i.. siphon).  

 

For the piping appropriate directions should be observed  i.e. compensation of  potential ! 

 

With  free-sucking  apparatuses  the  humid  air  exhaust  should  be  removed  with  a    90°-bend  from 
the  apparatus  resp.  to  the  air  suction  at  least  a  distance  of  approx.  1.5m  should  be  applied,  to 
avoid an air short circuit with the humid exhaust air.  

 

For all  connections (air technical, electrical) local indications/regulations should be observed.  

 

Содержание U7002

Страница 1: ...Operation Instructions U7002 and U7003 with control device U7100 ...

Страница 2: ...ir dehumidifier in a safe way This operation manual in particular the safety instructions should be met by all persons who operate the air dehumidifier In addition the rules and instructions for the working place to prevent accidents should be met Obligation of the Operator The operator is obliged to have only persons operate the air dehumidifier who are familiar with the relevant instructions on ...

Страница 3: ... will not be liable Air dehumidifiers should not be put up in liquids or suck up liquids f i full tanks or flooded surfaces etc The operation in and or with explosion sensitive atmosphere is permitted for RL 94 9 EG Atex 95 marked apparatuses The owner is obliged to check the ability of deployment of the air dehumidifier in accordance with the RL 1999 92 EG Atex 137 To use in accordance with its o...

Страница 4: ...r Without written authorization of Totech Europe Ltd no changes building on or adding to especially welding work on carrying parts of the dehumidifier should be made Only original parts should be used because otherwise no functional and safe operation is guaranteed Cleaning of the dehumidifier and storage of waste Substances and materials used should be applied and stored as waste in an expert way...

Страница 5: ...0 C at 60 r H With diminishing relative humidity the process air and or increasing relative humidity of the regeneration air the dehumidifying performance is affected negatively A The air dehumidifier should only be used with surrounding temperatures between 20 C und 40 C B The temperature of the process air sucked up should at most be 40 C and the temperature of the regeneration air should at lea...

Страница 6: ...humidity is adsorbed with the silicagel rotor Picture 1 Way of operation U 7002 U 7003 During rotation the rotor passes through two sectors Regeneration D and Process A The bigger Process Air current P is dehumidified in the Process Sector Adsorbtion The smaller Regeneration Air current R is heated by the Heater 5 to remove the adsorbed water by silicagel in the Regeneration Sector Desorbtion R 3 ...

Страница 7: ...on of the vapour possible and offers the extremely high adsorption capacity of the silicagel rotor The special construction of the rotor material brings about that the silicagel is not interfered by saturated air f i because of a failure of the heater or the regeneration air or with a stagnation of the rotor Through this the air dehumidifier can also be used with saturated air Through the fixed co...

Страница 8: ...ressure indication serves the optical check of the present differential pressure on the filter It is fitted as a mechanical manometer and does not need an extra energy Logic module The apparatus has been provided with a free programmable logic module which has been installed in the U 7100 This will take over the steering the adjustment of the regeneration air temperature and the function guarding ...

Страница 9: ... fresh air B Way of putting uo outside the room to be dehumidified The apparatus can be connected in regenerated air or fan air operation Herewith a connection should be put up for the dried air to the dehumidifying room Here also applies that with regenerated air the regenerated part is to be compensated with fresh air The apparatus has been constructed in such a way that the air channels as well...

Страница 10: ...pprox 1 h The unit can be stopped by pressing the ON key on the display 6 Adjusted values By pressing the SET key for some time you will get to the adjustment menu Here you can carry out the adjustments by means of the and keys By pressing the SET key for a short time you will get to the following adjustment menus succesively Humidity Humidity alarm Delayed alarm Temperature for optional heating L...

Страница 11: ...now protected from unintentionally changing of the parameter If you want to change the adjusted values both keys should be pressed for 5 seconds till the report Released shows up Now you will have full access to all functions again 9 Calibration To calibrate the drying unit we recommend 2 ways a Exchanging the sensor for a functional calibration sensor The insertable sensor can simply be changed a...

Страница 12: ...nection can be separated The installation takes place in reverse order Changing of the filter The periods between filter change depend on the degree of pollution of the air and the quality of the filter Filthy filters affect the performance of the air dehumidifiers Therefore they should be checked once a week and when filthy be exchanged However it is recommended to check and exchange the filter a...

Страница 13: ... contact exchange if necessary Ventilator exchange Check electrical components acc circuit diagram No report Apparatus switched off Mains switch in cold apparatus element switched off Main fuse gone Use ON key on display Check electrical components acc circuit diagram Fuses Steering tension Fuses gone Exchange of fuses Check electrical components acc circuit diagram Report Sensor failure Sensor go...

Страница 14: ...licagel which causes loss in performance Nr Substancies chem Formula Effects 1 Lithiumchloride LiCl Decrease in performance of the silicagel 1 2 Natriumhydroxide NaOH Disruption of the silicagel structure 3 Kaliumhydroxide KOH Disruption of the silicagel structure 4 Natriumchloride NaCl Decrease in performance of the silicagel 1 5 Kaliumchloride KCl Decrease in performance of th silicagel 1 6 Kalz...

Страница 15: ...ilicagel 1 6 p Xylen C6H4 CH2 2 Decrease in performance of the silicagel 1 7 Phenol C6H5OH Decrease in performance of the silicagel 1 8 O dichlorobenzen C6H4CL2 Decrease in performance of the silicagel 1 9 Methylbromide CH3Br Decrease in performance of the silicagel 1 10 Glycerin C3H8O3 Decrease in performance of the silicagel 1 Obs 1 Decreases the internal pore surface of the silicagel which caus...

Отзывы: