Press the HUMIDITY button to leave the Humidity
Control screens (if no buttons are pressed, the display
will leave the Humidity Control screens after 30 seconds).
Press the HUMIDITY button
to enter the Humidification
Setup screens.
HUMIDITY
Adjust the desired
dehumidification setpoint
(25%-99%)
NOTE:
Each step # is located at
the top right corner of the
display for easy reference.
HUMIDITY
40
DeHumidify
99
Setup
2
Current Room Humidity
Page 10.3
If your HVAC unit is equipped with a dehumidification terminal the
thermostat will provide power to the appropriate terminal on the
backplate of the thermostat when the humidity in the home is above
the setpoint you have chosen. When the indoor humidity rises above
the setpoint you have selected, the appropriate terminal will be
de-energized. The value for this setpoint ranges from 25% to 99%.
Adjusting the Dehumidification Setpoint
Adjusting the Dehumidification Setpoint
Press
Dehumidification Notes:
Press the button to set the
dehumidification setpoint to 99% for no dehumidification operation.
This will lockout Advanced Setup steps 9, 10, and 11 (see pages
10.4 - 10.5).
You cannot set the dehumidify setpoint any lower than the humidify setpoint; a
5% differential is forced between the humidify and dehumidify setpoints.
NOTE: Due to variations in environmental conditions, it is not always possible
to achieve the desired humidification or dehumidification setpoint.
TOTALINE
10
Содержание P374-1 900