TOTAI

Model

Heat Output

13.0 KW

Gas Types

LPG

Injector Size

Ø 1.90mm x 1

Operating Pressure

2.8 kPa

Gas Consumption (at Max )

940 g/h

PROBLEM

PROBABLE CAUSE

SOLUTION

Gas valve may be OFF

Turn the gas valve ON

LPG cylinder empty

Refill LPG cylinder

Orifice blocked

Clean or replace Orifice

Air in supply system

Purge air from lines

Pilot will not light

Loose connection

Check all fittings

Debris around pilot

Clean dirty area

Loose connection

Tighten connection

.

Thermocouple bad

Replace Thermocouple

Gas leak in line

Check connections

Pilot will not stay on

Lack of gas pressure

LPG cylinder is near empty

Gas pressure is low

LPG cylinder is near empty

Orifice blocked

Remove, clean and replace

Control knob not ON

Turn knob to ON

.

Thermocouple bad

Replace Thermocouple

Burner will not light

Pilot light assembly bent
or not in correct location

.

Place pilot light in correct ositi

p

on

and retry

Repairs to the patio heater may only be carried out by a qualified technician

TAMPERING:
Under no circumstances are you allowed to tamper with the jet sizes or modify anything on
the appliance. Not only is it dangerous , it will also nullify your warranty

NOTE:

GAS-PRESSURE REGULATOR—This appliance is designed to operate on a gas pre sure

s

of 2,8 kPa.

A suitable bullnose regulator that complies with the requirements of SANS 1237

must be used with this appliance

Technical Specifications

Troubleshooting

FOR OUTDOOR USE ONLY
Specifications are subject to change without prior notice

16/DK1025

Содержание 16/DK1025

Страница 1: ...quids in the vicinity of this or other any other appliance Any LPG cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING HAZARDOUS FIRE OR EXPLOSION...

Страница 2: ...anel or top canopy reflector Control compartment burner and circulation air passageways must be kept clean Frequent cleaning may be necessary as required The LPG Cylinder should be turned off when the...

Страница 3: ...firm ground Never operate heater in an explosive atmosphere like in areas where petrol or other flammable liquids or vapours are stored To protect heater from strong wind anchor the base securely to t...

Страница 4: ...released after the pilot flame lights The pilot flame can be seen and checked from the small round window with a sliding cover located at the bottom of the flame screen to the left or right side of th...

Страница 5: ...ater with cleaners that are combustible or corrosive Remove debris from the burner to keep it clean and safe for use Cover the burner unit with the optional protective cover when the heater is not in...

Страница 6: ...3 pcs ground fixer 6 Stand with LPG cylinder housing and 3 post brackets 9 Cup Nuts M6 mm 9 Small Screws M6 x 10 mm 9 Small Flat Washers 6 mm for Reflector Assembly 6 Large Bolts and Flange Nuts M6 f...

Страница 7: ...M8x15 to join the post brackets and stand STEP 2 2 1 Put the post on the top of 3 pcs post brackets 2 2 Use 6 Large Bolts and Flange Nuts M6 to connect the post to the 3 pcs post brackets Tighten the...

Страница 8: ...al post and burner are assembled according to instructions and all bolts and nuts are tightened 5 2 Put 6 pcs Large Flat Washers on 3 Reflector Spacers Fasten the reflector with 3 pcs Large Flat Washe...

Страница 9: ...rest it on the post plate cylinder 7 2 Connect the regulator to the gas tank and tighten it with adjustable wrench 7 3 Connect the end thread of inlet gas hose to the regulator 7 4 Put LPG on the sta...

Страница 10: ...G cylinder is near empty Gas pressure is low LPG cylinder is near empty Orifice blocked Remove clean and replace Control knob not ON Turn knob to ON Thermocouple bad Replace Thermocouple Burner will n...