background image

MILLENIUM FREESTANDING MANUAL 2014

 

PYROGLOW® Gas Logs:   ADVANTAGES- Realistic surface textures & colours. Radiant       

natural glow  of an actual fire when burning. Natural looking logs when idle. Superior strength 

versus ceramic fibre.    Inert refractory formulation is ceramic fibre free. Pyroglow® logs create 

virtually no fume emission.   Thermal shock resistant. Contains no asbestos.

THESE APPLIANCES HAVE BEEN TESTED IN ACCORDANCE WITH AG 103 FOR 

 INSTALLATION AND OPERATION AS DESCRIBED IN THIS MANUAL  AND HAVE BEEN 

 CERTIFIED BY THE AUSTRALIAN GAS ASSOCIATION.

                                                                   

 WARNING:

All ILLusion Gas Log Appliances MUST be installed and serviced by an authorised installer or   technician.

 Unauthorised installation, service or maintenance may cause a hazardous situation.

    OWNERS INSTRUCTION & INSTALLATION MANUAL. PLEASE KEEP FOR FUTURE REFERENCE

MILLENIUM  GAS  LOG  HEATERS

       

HEAD OFFICE

145 STH. GIPPSLAND HWY. DANDENONG

VICTORIA AUSTRALIA 3175

PH:   (613) 9793 7520         

     

Email [email protected]

www.Illusionfires.com.au

 Illusion Australia Pty. Ltd.

The Illusion

Gas Log Fire

with 

PYROGLOW

®

Содержание MILLENIUM UGL32LP

Страница 1: ...103 FOR INSTALLATION AND OPERATION AS DESCRIBED IN THIS MANUAL AND HAVE BEEN CERTIFIED BY THE AUSTRALIAN GAS ASSOCIATION WARNING All ILLusion Gas Log Appliances MUST be installed and serviced by an authorised installer or technician Unauthorised installation service or maintenance may cause a hazardous situation OWNERS INSTRUCTION INSTALLATION MANUAL PLEASE KEEP FOR FUTURE REFERENCE MILLENIUM GAS ...

Страница 2: ...AG 103 NOTE ILLUSION GAS LOG HEATERS MODELS UGL33NG UGL40NG ARE DESIGNED AND TESTED TO BE INSTALLED WITH THE SUPPLIED FLUE KIT ONLY THESE UNITS MUST ONLY BE INSTALLED BY AN AUTHORISED INSTALLER TABLE OF CONTENTS PAGE DESCRIPTION 1 UGL33 DIMENSIONS 2 UGL40 DIMENSIONS 3 MAIN GAS CONNECTION LABELLING 4 LIGHTING INSTRUCTIONS 5 INSTALLATION FOREWORD SAFETY INFORMATION 6 INSTALLATION INSTRUCTIONS 7 INST...

Страница 3: ...MILLENIUM FREESTANDING MANUAL 2014 Q u a l i t y Va l u e I n G a s L o g F i r e s 1 UGL33NG UGL33LP DIMENSIONS 670mm 698mm 552mm 750mm 496mm 453mm 698mm 670mm 36mm 50mm GAS INLET RHS REAR ...

Страница 4: ...MILLENIUM FREESTANDING MANUAL 2014 Q u a l i t y Va l u e I n G a s L o g F i r e s 2 UGL40NG UGL40LP DIMENSIONS 770mm 798mm 552mm 750mm 496mm 453mm 798mm 770mm 36mm 50mm GAS INLET RHS REAR ...

Страница 5: ...essure kPa 83 73 1 25 2 25 Gas Consumption Mj h 33 40 28 37 Gas Type NAT NAT LP LP Average Efficiency 76 1 77 9 72 72 Max Output kW h 7 19 8 6 5 74 7 58 Main Gas Connection The connection is made using gas pipes with Rp1 2 ISO 7 threading Torque 25Nm If alternatively flanges are used first screw the pipes on to the flanges and then the flanges to the valve Recommended torque for the flange fixing ...

Страница 6: ...NEIGHBOURS HOME IF YOU CAN SMELL GAS DO NOT USE MOBILE PHONES OR ANY ELECTRICAL APPLIANCE OR ELECTRIC SWITCH IN THE BUILDING PILOT FLAME IGNITION Depress and turn the control knob to the PILOT position Depress the button and ignite the pilot flame by pressing the red igniter button while keeping the knob fully depressed for a few seconds Fig 1 Release the knob slowly and check that the pilot flame...

Страница 7: ...pliance must be installed with an approved flue system which terminates outside the building A flue system must never terminate within the roof cavity 5 The unit should be checked periodically for lint The fan area especially is prone to lint build up during normal operation Keep the area around the appliance clean and free from lint 6 Only persons familiar with the operation of the unit should us...

Страница 8: ... kit part number LS1 and Model UGL40NG requires Log kit part number LS2 Check to see that the correct log kit is supplied Open the FLUE KIT carton and check to see all components are supplied including the flue lengths outer casing mounting brackets gas cowl FLASHING IS NOT INCLUDED AND MUST BE SUPPLIED BY THE INSTALLER 3 POSITION THE HEATER Place the heater in the required position as determined ...

Страница 9: ...UGL33LP and UGL40LP must only be installed with the minimum distances shown below Note that these appliances have a DRAFT DIVERTER at the rear of the unit which exits at the rear and must not be altered obstructed or blocked in any way Modifications or obstructions to the draft diverter or exit may cause a hazardous situation 1 0 0 mm NOTE MINIMUM DISTANCE FROM TOP OF HEATER TO CEILING IS 1500mm ...

Страница 10: ...MILLENIUM FREESTANDING MANUAL 2014 Q u a l i t y Va l u e I n G a s L o g F i r e s 8 INSTALLATION EXAMPLES ...

Страница 11: ...e ceramic pin in the middle hole of log number 1 Place log number 4 over middle pin in rear log and right pin in the burner plate Note the positions of the bumps in log No 4 The narrow end of log number 4 is towards the rear of the heater 5 Place log number 5 at a 45º angle over the remaining pins in the burner plate The chop mark in the log is towards the front of the heater 6 Insert remaining pi...

Страница 12: ...Q u a l i t y Va l u e I n G a s L o g F i r e s FITTING THE LOG SET MODELS UGL32NG UGL32LP UGL33NG UGL33LP INSTALLATION SEQUENCE 1 2 3 4 5 6 ADD COALS AS THE LOGS ARE FITTED 2 2 3 3 4 4 1 1 6 6 LOGS ARE NUMBERED ON THE UNDERSIDE 5 5 10 ...

Страница 13: ...serted the height of the rear end of log B should be approximately level with the top of log A 5 Insert a ceramic pin and the metal spacer into the second from right hole in log A The pointed end of the spacer should face up Insert log D over the pin spacer in log A and the remaining pin in the burner plate The end with the bumps should face towards the front of the heater When fully inserted log ...

Страница 14: ... a l i t y Va l u e I n G a s L o g F i r e s FITTING THE LOG SET MODELS UGL39NG UGL39LP UGL40NG UGL40LP 12 INSTALLATION SEQUENCE A E F B D G C 1 7 6 4 2 5 3 LOGS ARE NUMBERED ON THE UNDERSIDE A E F B D G C ADD COALS AS THE LOGS ARE FITTED ...

Страница 15: ... AND SHOULD BE CHECKED AT THE PRESSURE TEST POINT SEE BELOW NOTE BOTH INLET AND MANIFOLD PRESSURES SHOULD BE CHECKED USING THE VALVE PRESSURE PORTS ON THE GAS VALVE PROCEDURE TURN VALVE TO OFF POSITION LOOSEN INLET PRESSURE POINT 5 ATTACH MANOMETER TO INLET PRESSURE POINT 5 LIGHT THE PILOT SEE LIGHTING INSTRUCTIONS TURN VALVE TO ON THE PRESSURE SETTING MUST BE WITHIN THE LIMITS SPECIFIED ON THE CO...

Страница 16: ... FANS AND OTHER GAS APPLIANCES IN THE HOME SHOULD BE RUNNING WHEN THE HEATER IS TESTED FOR FLUE SPILLAGE TO TEST FOR SPILLAGE THE HEATER SHOULD BE LIT AND SET TO HIGH WAIT 10 MINUTES THEN TEST FOR DRAFT AT THE BASE OF THE DRAFT DIVERTER WITH A SMOKE MATCH CIGARETTE OR SIMILAR A CORRECTLY OPERATING UNIT WILL DRAW THE SMOKE FROM THE MATCH INTO THE DRAFT DIVERTER SEE BELOW IF THE FLUE IS BLOCKED OR N...

Страница 17: ...ames periodically The flames should be steady and not lifting off the burner holes If there is a problem call an authorized person or your local dealer 4 The appliance and flue system must be inspected by an authorized person before using and at least annually During this operation burner should be inspected and cleaned if required 5 Keep the area near the appliance clear and free from combustible...

Страница 18: ... s L o g F i r e s REMOVE TOP PANEL OF HEATER AS SHOWN ABOVE SWING BOTH LEFT AND RIGHT HAND SIDE DOORS OPEN WHILST PRESSING THE DOOR FORWARD PULL FOUR TOGGLE CLAMP LEVERS TOWARDS THE FRONT OF HEATER AND UNCLIP AS SHOWN REMOVE THE HEATER DOOR DOOR REMOVAL PROCEDURE 16 ...

Страница 19: ...ASSEMBLY 2 TOP PANEL 3 TOP MOUNTING PANEL 4 FIREBOX 5 FAN AIR DUCT 6 BACK PANEL 7 LHS COVER 8 RHS COVER 9 PARTITION PLATE 10 FAN COVER 11 FAN ASSEMBLY 12 PEDESTAL ASSEMBLY 13 PEDESTAL COVER Spare Parts Spare parts are available from your supplier Refer to rear of this manual for contact details 1 11 13 12 10 9 8 7 6 5 4 3 2 ...

Страница 20: ...nergy saving method of operating the fan SHUT DOWN It will also shut down the fan 10 to 15 minutes after the heater is turned off once the firebox has cooled sufficiently REMOTE CONTROLLER OPTION The above features apply even if the unit is fitted with a new OPTIONAL remote controller If the remote control is used to turn the appliance on the fan will only startup if the fan speed is set to LOW HI...

Страница 21: ...t require line of sight It is a fully featured programmable unit which can be wall mounted in the supplied cradle No need for a seperate wall thermostat The remote can be programmed for each day of the week to turn on and off when needed It also features a countdown timer which will turn the heater off after a set period CAN BE RETRO FITTED TO EXISTING MILLENIUM ESPRIT AND OPEN GAS FIRES NOT SUITA...

Страница 22: ...OCCURS ON THE LOGS AND OR DOOR GLASS 2 YOU CAN SMELL GAS 3 THE FLAME PATTERN IS INCONSISTENT AND APPEARS TO BE LIFTING OFF THE BURNER 4 YOU CAN SMELL THE PRODUCTS OF THE FLUE WITHIN THE ROOM IN WHICH THE APPLIANCE IS INSTALLED MAY BE AN INDICATION OF A BLOCKED FLUE IF ANY OF THESE SITUATIONS OCCUR TURN THE APPLIANCE OFF AND CONTACT YOUR SUPPLIER OR INSTALLER IMMEDIATELY IF YOU CAN SMELL GAS TURN T...

Страница 23: ...not active SOLUTION The gas valve sensor Thermopile may be faulty Contact your Dealer SYMPTOM The logs have a build up of black soot in some areas POSSIBLE CAUSE Usually indicates incorrect positioning of logs if the unit has just been installed If the unit has been installed for some time the inspirator may require cleaning Contact your Dealer SOLUTION Re position the logs as per instructions See...

Страница 24: ...o g F i r e s ILLUSION Gas Log Fires State Dealer Contact List 22 www Illusiongasheating com au service Illusionwoodheaters com au Va l u e Q u a l i t y I n G a s L o g F i r e s Head Office 145 Sth Gippsland Hwy Dandenong Sth Victoria Australia 3175 Phone 61 3 9793 7520 ...

Страница 25: ...Victoria Australia 3175 Telephone 613 9793 7520 Email service Illusionfires com au WEB www Illusionfires com au Illusion Australia Pty Ltd reserves the right to alter specifications contained in this publication without notice Illusion Australia Pty Ltd admits no responsibility for printing errors or omissions within this publication Copyright Illusion Australia Pty Ltd 2014 ...