MAINTENANCE
ANNUAL SERVICE SHOULD BE PERFORMED ONLY BY AN AUTHORISED
ILLUSION INSTALLER OR GAS FITTER.
1) Clean the burner and control compartment of lint and house dust by brushing and
Vacuuming at least once a year. When cleaning the logs, use a soft clean brush as
the logs are fragile and easily damaged.
During the annual service the burners should be removed from the burner tray and
cleaned.
2) When unit is cold, clean glass, louvres, and door with a damp cloth. Do not use abrasive
cleaners.
This heater is painted with a heat resistant paint. To retouch, refer to paint supplied by
manufacturer.
3) Check the flames periodically. The flames should be steady and not lifting off the burner
holes. If there is a problem, call an authorized person or your local dealer.
4) The appliance and flue system must be inspected by an authorized person before using and
at least annually. During this operation burner should be inspected and cleaned if required.
5) Keep the area near the appliance clear and free from combustible materials, gasoline
aerosols, and other flammable vapours and liquids
Replacing Logs
The unit should never be used with broken logs. Always turn the gas valve off. And allow the unit to
cool before opening door. Remove logs carefully.Logs should only be replaced by an Authorised ILLUSION
representative.
Note: Improper positioning of logs may create soot build up and carbon monoxide, which will affect heater
performance. Improper positioning or altering the position of logs will void your warranty.