I-9
Selection table of separate-type options
Radio noise reduction filter
Voltage
class
Applicable
motor
[kW]
Inverter
model
Input AC
reactor
(ACL)
DC reactor
(DCL)
High
attenuation
type
Simple
type
Core
type
(*1)
Braking resistor
/Braking unit
(*3, 4, 5)
Motor end
surge voltage
suppression
filter
Motor
noise
reduction
filter
18.5
VFP7-2185P
NF-3080A-MJ
PBR3-2150
22
VFP7-2220P
PFL-2100S DCL-2220
NF-3100A-MJ
PBR3-2220
30
VFP7-2300P
PB3-2300
37
VFP7-2370P
PFL-2150S DCL-2370 NF-3150A-MJ
45
VFP7-2450P
PFL-2200S DCL-2450 NF-3200A-MJ
RC9129
−
55
VFP7-2550P
PFL-2300S DCL-2550 NF-3250A-MJ
PB3-2550
NRL-2220
75
VFP7-2750P
PFL-2400S DCL-2750
NF-3200A-MJ
×
2 (parallel)
NRL-2300
90
VFP7-2900P
NRL-2400
200V
class
110
VFP7-2110KP
PFL-2600S DCL-2900
NF-3250A-MJ
×
2 (parallel)
RCL-M2
RC9129
(*6)
DGP600W-B1
[DGP600W-C1]
−
(*2)
18.5
VFP7-4185P
NF-3040C-MJ
PBR3-4150
22
VFP7-4220P
PFL-4050S DCL-4220
NF-3050C-MJ
PBR3-4220
MSF-4220Z
30
VFP7-4300P
NF-3060C-MJ
37
VFP7-4370P
NF-3080C-MJ
PB3-4300
MSF-4370Z
45
VFP7-4450P
PFL-4100S DCL-4450
NF-3100C-MJ
55
VFP7-4550P
RC9129
MSF-4550Z
−
75
VFP7-4750P
PFL-4150S DCL-4750 NF-3150C-MJ
MSF-4750Z NRL-4155
90
VFP7-4900P
PB3-4550
110
VFP7-4110KP
PFL-4300S DCL-4110K NF-3250C-MJ
NRL-4230
132
VFP7-4132KP
NRL-4300
160
VFP7-4160KP
PFL-4400S DCL-4160K
NF-3200C-MJ
×
2 (parallel)
DGP600W-B2
[DGP600W-C2]
NRL-4350
200
VFP7-4200KP
220
VFP7-4220KP
PFL-4600S DCL-4220K
NF-3250C-MJ
×
2 (parallel)
DGP600W-B3
[DGP600W-C3]
NRL-4600
280
VFP7-4280KP
NRL-4550
400V
class
315
VFP7-4315KP
PFL-4800S DCL-4280K
NF-3250C-MJ
×
3 (parallel)
RCL-M4
RC9129
(*6)
DGP600W-B4
[DGP600W-C4]
(*7)
(*2)
(*1): This filter needs to be wound 4 turns or more around with the input side power line. This filter can
be used for the output side in the same manner. For the wire whose size is 22 mm
2
or more, install
at least 4 filters in series. Round type (Model: RC5078) is also available.
(*2): For a motor noise reduction filter for this class, please consult.
(*3): PBR3-
□□□□
indicates braking resistor, PB3-
□□□□
indicates braking unit (dynamic braking
drive circuit and braking resistor(s) are built in it).
(*4): Model in square brackets is fitted with top cover.
(*5): To use 200 V-75 kW or more or 400 V-110 kW or more inverter with an external braking resistor
(DGP600 series), installation of a dynamic braking drive circuit inside the inverter is required.
(*6): There is a case that this filter is unusable depending on the type or size of the cable to be used.
(*7): About this filter for inverter models of 90 kW or more, consult with our office
(*8): Be sure to connect DC reactor to 200V-75kW or more or 400V-110kW or more inverter. (Not
necessary for DC input.)