F-27
3) Selection of braking resistor option and braking unit
braking resistor option / braking unit
Model
Type form
Rating
VFP7-2185P
PBR3-2150
220[W] - 30[
Ω
]
×
4P (880[W] - 7.5[
Ω
])
VFP7-2220P
PBR3-2220
220[W] - 27[
Ω
]
×
8P (1760[W] - 3.3[
Ω
])
VFP7-2300P
PB 3-2300
200[W] - 5[
Ω
]
×
3P2S (1200[W] - 3.3[
Ω
])
VFP7-2370P
〜
2550P
PB 3-2550
200[W] - 5[
Ω
]
×
5P2S (2000[W] - 2[
Ω
])
VFP7-2750P
〜
2110KP (*3)
DGP600W-B1
3.4[kW] - 1.7[
Ω
]
VFP7-4185P
PBR3-4150
220[W] - 120[
Ω
]
×
4P (880[W] - 30[
Ω
])
VFP7-4220P
PBR3-4220
220[W] - 30[
Ω
]
×
4P2S (1760[W] - 15[
Ω
])
VFP7-4300P
〜
4370P
PB 3-4300
200[W] - 20[
Ω
]
×
3P2S (1200[W] - 13.3[
Ω
])
VFP7-4450P
〜
4900P
PB 3-4550
200[W] - 20[
Ω
]
×
5P2S (2000[W] - 8[
Ω
])
VFP7-4110KP
〜
4160KP (*3)
DGP600W-B2
7.4[kW] - 3.7[
Ω
]
VFP7-4200KP
〜
4220KP (*3)
DGP600W-B3
8.7[kW] - 1.9[
Ω
]
VFP7-4280KP
〜
4315KP (*3)
DGP600W-B4
14[kW] - 1.4[
Ω
]
(*1) The values in ( ) are the total resistor capacities (watt) and resistances (
Ω
) of braking resistors.
(*2) Type form PBR3-
□□□□
: Braking resistor (Connected to PA, PB terminal.)
PB3-
□□□□
: Braking unit ( [Braking re Braking resistor drive circuit] are
installed. Connected to PA, PC terminal.)
DGP600W-B
□
: Braking resistor (Connected to PA, PB terminal.)
(*3) To use braking resistor(DGP600 series), installing a braking resistor drive circuit option is needed.
4) Connectable braking resistors and their minimum resistances
The table below lists externally-connectable braking resistors and their minimum ad
missible resistances. Do not connect any braking resistor with a resistance (total
resistance) smaller than the minimum resistance admissible for it.
200V class
400V class
Applicable motor
capacity [kW]
Standard
option [
Ω
]
minimum
resistance [
Ω
]
Standard
option [
Ω
]
minimum
resistance [
Ω
]
18.5 7.5
5
30
20
22
3.3
3.3
15
13.3
30
3.3
3.3
13.3
13.3
37
2
1.7
8
13.3
45
2
1.7
8
6.7
55
2
1.7
8
5
75
1.7
1.3
8
3.3
90
1.7
1
3.7
3.3
110
1.7
1
3.7
2.5
132
−
−
3.7
2.5
160
−
−
1.9
2.5
200
1.9
1
220
−
−
1.9
1
280
−
−
1.4
1
315
−
−
1.4
1