4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
EO18-33012B
(Revision Date Apr. 24, 2008)
4.22 RFID MODULE (B-SX704-RFID-U2-EU-R)
4-153
3) Set
an
AGC threshold of data write.
Set a value which is lower than the AGC value obtained by a read test by 1 or 2, taking variation of
RFID tags in performance into consideration.
Press the
[PAUSE]
key to implement a read test.
<10>RFID
READ TEST ON
[PAUSE]
<10>RFID
READING
•••
.
Read data is displayed.
3132333435363738
39304142 (0A)
Press the
[FEED]
and
[RESTART]
keys to return to the RFID Setting Menu
(”<10>RFID”).
<10>RFID
[FEED], [RESTART]
Data in parentheses ( ) is the AGC value expressed in hex. code. Write down this value.
<10>RFID
[PAUSE]
<10>RFID
Q VALUE 0
Choose “2” with the
[FEED]
or
[RESTART]
key.
When “2” is already chosen, go to the AGC threshold for data write setting menu.
[RESTART]
[FEED]
15
•
•
•
•
0 (Default)
<10>RFID
WT AGC 0
[FEED] or [RESTAT]
<10>RFID
WT AGC 9
AGC threshold for data write setting menu is displayed.
Choose a threshold value (decimal number) with the
[FEED]
or [
RESTART]
key.
When the measured AGC is 10 (0A), for example, choose “9” (a value lower than the
measured AGC by 1 or 2).
[RESTART]
[FEED]
15
•
•
•
•
0 (Default)
[PAUSE]
<10>RFID
Q VALUE 2
[FEED] or [RESTART]
[PAUSE]
Example
Press the
[PAUSE]
key.
When ”<10>RFID” is displayed, press the
[PAUSE]
key until the Q value setting menu is
displayed.
Press the
[PAUSE]
key.
<10>RFID
WT MIN AGC 0
AGC threshold lower limit for retry setting menu is displayed.
Choose a lower limit (decimal number) with the
[FEED]
or
[RESTART]
key.
Usually, choose the same value with the AGC threshold for data write (WT AGC).
[FEED] or [RESTAT]
<10>RFID
WT MIN AGC 9
[PAUSE]
[RESTART]
[FEED]
15
•
•
•
•
0 (Default)
Press the
[PAUSE]
key.
<10>RFID
RFID Setting Menu (”<10>RFID”) is displayed.
An AGC threshold setting is completed.
Continued from the previous page