Installation
Step 3: Connect Hardware to Strata CTX
10
Strata CTX Attendant Console Installation 03/03
Figure 2
Network Interface Connection
Figure 3
8-wire Modular Cord Pinouts
Important!
•
If a DKT telephone is connected to the CTX Attendant Console PC, use the keyboard for all
PC operations when the console is running. (When the console is in Position Busy, it is still
running.)
•
When the Attendant Console software is not running, the DKT3001 telephone can be used
for regular calling. Calls intended for an Attendant when the software is not running will
follow the Alternate Destination programmed in Strata CTX. Only calls directed to the DKT’s
primary extension number will ring the phone.
•
Also, if the handset interferes with the headset, you can unplug the handset while using the
headset.
6511
CTX100 ACTU
with AETS
or
CTX670 BBCU
processor
Strata CTX
Straight-pinned,
8-wire modular cord
Straight-pinned,
8-wire modular cord
RJ45
Jack
NIC
CTX
Attendant
Console
NIC
RJ45
Jack
RJ45
Jack
RJ45
Jack
LAN
or
Hub
PDKU
or
BDKU
BATI
MDF
White cord (supplied)
RJ11
Handset
Cradle
(BATHC)
Headset
or
DKT3001
with BHEU
RJ11
Headset
Amphenol
6512
Straight-pinned,
8-wire modular cord
Pin
Pin
1
2
3
6
1
2
3
6
TD+
TD-
RD-
TD-
RD-
RD+
TD+
RD+
Cross-pinned,
8-wire modular cord
1
2
3
6
3
6
1
2
Pin
Pin
TD+
TD-
RD-
TD-
RD-
RD+
TD+
RD+