430 Series
3-45
3.21 Log Utilities
3.21.1
Function Description
This function logs error information generated while a test is in progress and stores the
results in RAM. This function can store data on a floppy disk or output the data to a printer.
If the power switch is turned off, the error information will be lost. The error information is
displayed in the following order:
1.
Error count (CNT)
2.
Test name (TS-NAME)
3.
Subtest number (TS-NAME)
4.
Pass count (PASS)
5.
Error status (STS)
6.
FDD/HDD or memory address (ADDR)
7.
Write data (WD)
8.
Read data (RD)
9.
HDC status (HSTS)
10.
Error status name (ERROR STATUS NAME)
3.21.2
Operations
1.
Selecting
5
and pressing
Enter
in the DIAGNOSTIC MENU logs error informa-
tion into RAM or onto a floppy disk. The error information is displayed in the
following format:
XXXXX ERRORS
CNT TS-NAME PASS STS ADDR WD RD HSTS [STATUS NAME]
001 FDD 02 0000 103 00001 00 00 FDD - WRITE PROTECTED
001 FDD 01 0000 180 00001 00 00 FDD - TIME OUT ERROR
Address
Error status
Pass count HDC status
Subtest number Read data
Test name Write data
Error count Error status name
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
Содержание Satellite Pro 430CDS
Страница 1: ...TOSHIBA 430Series PN 430 9400 CASM 2970307 B00 ...
Страница 23: ...430 Series 2 3 Figure 2 1 Troubleshooting flowchart ...
Страница 172: ...430 Series B 1 Appendix B Board Layout B 1 System Board Front View Figure B 1 Board layout front ...
Страница 173: ...B 2 430 Series B 2 System Board Back View Figure B 2 Board layout back ...
Страница 184: ...E 2 430 Series E 3 German GR Keyboard Figure E 3 GR keyboard E 4 French FR Keyboard Figure E 4 FR keyboard ...
Страница 185: ...430 Series E 3 E 5 Spanish SP Keyboard Figure E 5 SP keyboard E 6 Italian IT Keyboard Figure E 6 IT keyboard ...
Страница 186: ...E 4 430 Series E 7 Scandinavian SC Keyboard Figure E 7 SC keyboard E 8 Swiss German SL Keyboard Figure E 8 SL keyboard ...