background image

AI C

ENTRAL

 R

EMOTE

 C

ONTROLLER

– 3 –

S

YSTEM

 G

UIDELINES

 

AND

 F

UNCTIONS

4

N

AMES

 

AND

 F

UNCTIONS

 – C

ENTRAL

 R

EMOTE

 C

ONTROLLER

 D

ISPLAY

5

C

ENTRAL

 R

EMOTE

 C

ONTROLLER

 B

UTTON

 O

PERATIONS

6

O

PERATION

 P

ROCEDURE

7

S

INGLE

 G

ROUP

 S

ELECTION

 P

ROCEDURE

8

U

NIT

 S

ETTING

 P

ROCEDURE

9

T

IMER

 O

PERATION

10

O

PERATION

 R

ESTRICTION

11

M

ONITORING

 

AND

 F

ILTER

 S

IGN

12

C

ONTENTS

G

ÉNÉRALITES

 

ET

 F

ONCTIONS

13

D

ÉSIGNATIONS

 

ET

 F

ONCTIONS

 – Z

ONE

 

D

'

AFFICHAGE

 

DE

 

LA

 

TÉLÉCOMMANDE

 

CENTRALE

14

B

OUTONES

 

DE

 

LA

 T

ÉLÉCOMMANDE

 C

ENTRALE

15

P

ROCÉDURE

 

DE

 F

ONCTIONNEMENT

16

P

ROCÉDURE

 

DE

 S

ÉLECTION

 

DES

 U

NITÉS

17

P

ROCÉDURE

 

DE

 R

ÉGLAGE

 

DES

 U

NITÉS

18

F

ONCTIONNEMENT

 

AVEC

 

LE

 P

ROGRAMMATEUR

19

L

IMITATION

 

DE

 

L

'

ACCÈS

 

AUX

 F

ONCTIONS

20

C

ONTRÔLE

 

ET

 T

ÉMOIN

 

DE

 F

ILTRE

21

S

OMMAIRE

A

LLGEMEINES

 

UND

 F

UNKTIONEN

22

B

EZEICHNUNGEN

 

UND

 F

UNKTIONEN

 – A

NZEIGEFELD

 

DER

 Z

ENTRALEN

 F

ERNBEDIENUNG

23

T

ASTEN

 

DER

 Z

ENTRALEN

 F

ERNBEDIENUNG

24

B

ETRIEB

25

W

ÄHLEN

 

DER

 A

NLAGEN

26

E

INSTELLEN

 

DER

 A

NLAGEN

27

Z

EITREGLERBETRIEB

28

E

INSCHRÄNUNG

 

DES

 Z

UGRIFFS

 

AUF

 F

UNKTIONEN

29

Ü

BERWACHUNG

 

UND

 FILTER-A

NZEIGE

30

I

NHALT

I

NTRODUCCIÓN

 

AL

 S

ISTEMA

 

Y

 F

UNCIONES

31

N

OMBRES

 

Y

 F

UNCIONES

 – D

ISPLAY

 

DEL

 M

ANDO

 

A

 D

ISTANCIA

 C

ENTRAL

32

F

UNCIONAMIENTO

 

DE

 

LOS

 B

OTONES

 

DEL

 M

ANDO

 

A

 D

ISTANCIA

 C

ENTRAL

33

M

ÉTODO

 O

PERATIVO

34

M

ÉTODO

 

DE

 S

ELECCIÓN

 

DE

 

UNA

 U

NIDAD

 I

NDIVUDAL

/

UN

 G

RUPO

 

DE

 U

NIDADES

35

M

ÉTODO

 

DE

 P

ROGRAMACIÓN

 

DE

 

UNA

 U

NIDAD

36

F

UNCIONAMIENTO

 

DEL

 T

IMER

37

L

IMITACIÓN

 

DEL

 F

UNCIONAMIENTO

38

M

ONITORIZACIÓN

 

Y

 S

ÍMBOLO

 

DEL

 F

ILTRO

39

G

ENERALITÀ

 

E

 F

UNZIONI

40

N

OMI

 

E

 F

UNZIONI

 – D

ISPLAY

 

DEL

 T

ELECOMANDO

 C

ENTRALE

41

F

UNZIONI

 

DEI

 P

ULSANTI

 

DEL

 T

ELECOMANDO

 C

ENTRALE

42

P

ROCEDURA

 O

PERATIVA

43

P

ROCEDURA

 

DI

 S

ELEZIONE

 

DELLE

 U

NITÀ

44

P

ROCEDURA

 

DI

 R

EGOLAZIONE

 

DELLE

 U

NITÀ

45

F

UNZIONAMENTO

 

DEL

 T

IMER

46

I

MPOSTAZIONE

 

DELLE

 L

IMITAZIONI

 

AL

 F

UNZIONAMENTO

47

M

ONITORAGGIO

 

E

 S

IMBOLO

 

DEL

 F

ILTRO

48

I

NDICE

R

ICHTLIJNEN

 V

OOR

 H

ET

 S

YSTEEM

 

EN

 F

UNCTIES

49

B

ENAMINGEN

 

E

 F

UNCTIES

 – D

ISPLAY

 

VAN

 C

ENTRALE

 A

FSTANDSBESTURING

50

W

ERKING

 

VAN

 

DE

 K

NOPPEN

 

VAN

 

DE

 C

ENTRALE

 A

FSTANDSBESTURING

51

P

ROCEDURE

 

VOOR

 H

ET

 

IN

 W

ERKING

 S

TELLEN

52

S

ELECTIEPROCEDURE

 A

FZONDERLIJK

/G

ROEP

53

P

ROCEDURE

 

OM

 

DE

 E

ENHEID

 

IN

 

TE

 S

TELLEN

54

W

ERKING

 

VAN

 

DE

 T

IMER

55

B

EPERKING

 

VAN

 

DE

 W

ERKING

56

C

ONTROLE

 

EN

 F

ILTERSYMBOOL

57

I

NHOUD

GB

F

D

E

C

ONTENIDO

I

NL

Содержание RBC-CR1-PE

Страница 1: ...LLER OWNER S MANUAL TELECOMMANDE CENTRALE AI MODE D EMPLOI ZENTRALE FERNBEDIENUNG AI BENUTZERHANDBUCH MANDO A DISTANCIA CENTRAL AI MANUAL DEL USUARIO TELECOMANDO CENTRALE AI MANUALE DELL UTENTE AI CENTRALE AFSTANDSBESTURING GEBRUIKERSHANDLEIDING 1401449201R01 TOSHIBA ...

Страница 2: ...e bitte das jeweilige Handbuch Das Handbuch immer leicht auffindbar aufbewahren Este manual contiene las instrucciones para el manejo del mando a distancia Lea este manual detenidamente antes de usar su acondicionador de aire Para las unidades de interior y exterior consulte los manuales del usuario correspondientes Mantenga este manual en un lugar conveniente para poder consultarlo en el futuro Q...

Страница 3: ...G UND FILTER ANZEIGE 30 INHALT INTRODUCCIÓN AL SISTEMA Y FUNCIONES 31 NOMBRES Y FUNCIONES DISPLAY DEL MANDO A DISTANCIA CENTRAL 32 FUNCIONAMIENTO DE LOS BOTONES DEL MANDO A DISTANCIA CENTRAL 33 MÉTODO OPERATIVO 34 MÉTODO DE SELECCIÓN DE UNA UNIDAD INDIVUDAL UN GRUPO DE UNIDADES 35 MÉTODO DE PROGRAMACIÓN DE UNA UNIDAD 36 FUNCIONAMIENTO DEL TIMER 37 LIMITACIÓN DEL FUNCIONAMIENTO 38 MONITORIZACIÓN Y ...

Страница 4: ...rity All air conditioner functions can be changed by either Remote Controller Central The air conditioner settings can be modified by the Central Remote Controller The air conditioner can only be switched on and off by the Standard Remote Controller Central Locked The air conditioner is locked in the off position FILTER SIGN As a reminder to clean the filters this is displayed on the Standard Remo...

Страница 5: ...d operation mode 7 FAN Display Displays selected fan speed 8 TEMP Display This display shows the set temperature 9 CHECK Display This display appears when the air conditioner is in the check mode 10 LOUVER or LOUVER Display MANUAL LOUVER is displayed if the automatic louvers are driven LOUVER MANUALis displayed if auto louver is selected but not available 11 TIMER Display This is displayed when a ...

Страница 6: ...it is pressed the display changes in the following sequence FAN ONLY COOL HEAT AUTO 7 FAN Button Selects the desired fan speed mode each time it is pressed the display changes in the following sequence AUTO HIGH MED LOW 8 LOUVER Button This is used to drive the outlet louvers automati cally when the air conditioner is in operation When it is pressed the louvers will start oscillation and LOUVER wi...

Страница 7: ...he Central mode operation of the air conditioner is restricted to ON OFF operation LOCKED In the Locked mode the air conditioner remains in the OFF mode Press the MONITOR SET button 8 To register the changes the Central Remote Controller will change to monitor The respective air conditioners will start If the new settings are not registered by pressing the MONITOR SET button within 15 seconds of t...

Страница 8: ...cation by pressing this button Each time this button is pressed the display scrolls through the number of each connected indoor units 3 SELECT ALL Button If all of the air conditioners connected to the Central Remote Controller require the same setting press this button and they will be selected SET ALL will flash 4 Indoor unit setting this is explained in detail on the following page 5 ON OFF But...

Страница 9: ...louver it can be switched on and LOUVER will be displayed 7 ON OFF Button When this key is pressed the selected air conditioner will be switched on or off when the set button is pressed 8 To register changes to the operating conditions of the air conditioners press the MONITOR SET Button The display changes from set to monitor If the operation of the air conditioner is stopped and immediately rest...

Страница 10: ...will begin to flash on the display 2 SINGLE SELECT SELECT ALL Buttons Select the unit s whose settings require modification by pressing these buttons 3 TIMER Button To select the timer press the timer button this associates the connected timer with the selected unit If TIMER is not displayed it is not associated with that unit 4 Indoor unit setting is explained in detail on page 9 5 To register ch...

Страница 11: ...OL Button Pressing this key can restrict the operation from the Local Remote Controller NO DISPLAY Last Push Priority CENTRAL Is displayed the operation of the Remote Control is restricted to on and off operation LOCKED Is displayed the selected air conditioner is locked in the off position 4 Indoor unit setting is explained in detail on page 9 5 To register changes to the operating conditions of ...

Страница 12: ... stepped through 1 SINGLE SELECT Button Press this button to select the air conditioner with the FILTER sign illuminated 2 FILTER Sign When this sign is displayed it acts as a reminder to clean the filters Details for the filter cleaning are contained in the respective owner s manuals 3 Resetting of the filter sign This is done by pressing the filter button for 5 Seconds FILTER SIGN After 2500hrs ...

Страница 13: ...AI CENTRAL REMOTE CONTROLLER 00 60 AI CENTRALE AFSTANDSBESTURING TOSHIBA AIR CONDITIONING www toshiba aircon co uk MADE IN UK 1401449201R01 ...

Отзывы: