– 9
3
–
FILE NO. SVM-13047
No.
4
Part name
Exchange of
electric parts
(Continued)
Procedure
1. Reactor
1) Carry out works of 1 of
1
and
3
.
2) Remove the relay connector connected to
the control P.C. board.
3) Cut off the bundling band binding the
compressor lead and the relay connector.
4) Remove each reactor.
(Truss B tight screw Ø4 × 6, 2 pcs. each)
5) Attach a new reactor.
NOTE:
Be sure to bind the removed bundling band with
the bundling band on the market.
Be careful that the fan motor lead does not come
to contact with the reactor body.
Remarks
Reactor relay connector
(Connected to lead wire
(White) at P.C. board side)
Reactor relay connector
(Connected to lead wire
(Charcoal gray) at P.C. board side)
Fan motor lead
Bundling band
(Compressor lead, reactor lead)
Upper reactor
Connected to reactor relay connector
(Connected to lead wire (White)
at P.C. board side)
Bundling band
Lower reactor
Connected to reactor relay connector
(Connected to lead wire (Charcoal gray)
at P.C. board side)
SVM-12085_051-114.indd 94
SVM-12085_051-114.indd 94
12/06/12 11:15 AM
12/06/12 11:15 AM
Содержание RAV-SP564ATP-A
Страница 17: ... 17 FILE NO SVM 13047 2 CONSTRUCTION VIEWS EXTERNAL VIEWS 2 1 RAV SP56 ATP ...
Страница 18: ... 18 FILE NO SVM 13047 2 2 RAV SP80 ATP ...
Страница 23: ... 23 FILE NO SVM 13047 1 4 WIRING DIAGRAM 4 1 RAV SP56 ATP ...
Страница 24: ... 24 FILE NO SVM 13047 4 2 RAV SP80 ATP ...
Страница 100: ... 100 FILE NO SVM 13047 1 11 1 RAV SP564ATP A 11 EXPLODED VIEWS AND PARTS LIST ...
Страница 102: ... 102 FILE NO SVM 13047 TD TS TE TO 705 708 710 704 702 701 703 711 707 712 706 Inverter assembly ...
Страница 104: ... 104 FILE NO SVM 13047 11 2 RAV SP804ATP A ...
Страница 106: ... 106 FILE NO SVM 13047 Inverter assembly 1 2 3 705 709 710 711 707 704 706 703 701 708 702 712 713 ...
Страница 109: ......