– 64 –
Red
White
Black
Connector : White
Red
White
Black
Table Inspection of outdoor unit main parts
No.
1
2
3
Parts name
Compressor
(Model : DA422A3F-27M)
Outdoor fan motor
(Model : ICF-280-A100-1)
4-way valve coil
(Cooling/heating switching)
(Model : STF-01AJ502E1)
Checking procedure
Measure the resistance value of each winding by using the tester.
Position
Red – White
White – Black
Black – Red
Resistance value
0.79 ± 0.04
Ω
Under 20°C
Measure the resistance value of each winding by using the tester.
Position
Red – White
White – Black
Black – Red
Resistance value
14.8 ± 1.5
Ω
Under 20°C
Measure the resistance value of each winding by using the tester.
Resistance value
1435 ± 144
Ω
Under 20°C
Содержание RAV-SP1104AT8-E1
Страница 19: ... 19 4 WIRING DIAGRAM 4 1 Outdoor Unit RAV SP1104AT8 J E1 TR1 RAV SP1404AT8 J E1 TR1 RAV SP1604AT8 J E1 TR1 ...
Страница 113: ... 113 Outdoor Unit RAV SP1404AT8 E1 RAV SP1404AT8J E1 RAV SP1404AT8 TR1 RAV SP1404AT8J TR1 ...
Страница 117: ... 117 Outdoor Unit RAV SP1604AT8 E1 RAV SP1604AT8J E1 RAV SP1604AT8 TR1 RAV SP1604AT8J TR1 ...