– 107 –
RAV-SM800AT-E LED display when SW800 : Bit 1, 2, 3, 4 OFF
• When multiple errors are detected, the latest error is displayed.
• While LED displays
(go on), there is the main cause of error in control at CDB side and it stops abnormally.
• While LED displays
(flash), there is the main cause of error in control at IPDU side and it stops abnormally.
• For an error in case thermo operation, the communication is interrupted on the serial circuit. If continuing the
case thermo operation, serial sending to the indoor unit is interrupted and a serial communication error is
output.
Table A
CDB side
IPDU side
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Item
TE sensor error
TD sensor error
TS sensor error
TO sensor error
Discharge temp error
Out DC fan error
Communication error between IPDU
(Abnormal stop)
High-pressure release operation
EEPROM error
Communication error between IPDU
(No abnormal stop)
G-Tr short-circuit protection
Detection circuit error
Current sensor error
Phase missing detection
Comp lock error
Comp breakdown
Check code
B type
18
19
18
1B
1E
1A
1C
21
—
—
—
14
16
17
17
1D
1F
LED display
D800
D801
D802
D803
(Red)
(Yellow)
(Yellow)
(Yellow)
: Go on,
: Go off,
: Flash (5 Hz)