EN
6
Energy
saving
Set for the energy saving operation: Energy saving operation, Set temp. range limit, Return back and Saving
operation.
Energy saving(1/2)
1.Energy saving operation
2.Set temp. range limit
3.Return back
<ON>
<OFF>
Set
Return
1
Push the [
∧
] / [
∨
] button to select
“9. Energy saving” on the menu screen, then push
the “
Set
Set” [ F2] button.
2
Push the [
∧
] / [
∨
] button to select
the item to set.
3
Push the “
Set
Set” [ F2] button.
Item
Function
1. Energy saving operation
Perform the power saving operation of the air conditioner.
2. Set temp. range limit
Set the temperature range limit of the remote control operation.
3. Return back
Set the function that changes the temperature back to the speci
fi
ed
temperature automatically if the temperature has been changed on
the remote control.
4. Saving operation
Performs operation by suppressing excessive heating or excessive
cooling through automatic correction of the temperature set point.
* “No function” is displayed in the case of a model for which the
saving operation cannot be set.
CAUTION
Refer to the Owner’s Manual supplied with the air conditioner about “Energy saving operation”, “Saving operation”.
■
Energy saving operation
Set for the power saving operation of the air conditioner.
Energy saving operation
1.Energy saving operation
2.Energy saving ratio
3.Energy saving schedule
ON / OFF
Return
Fix
1
Push the [
∧
] / [
∨
] button to select
“1. Energy saving operation” on the
“Energy saving” screen.
2
To start the Energy saving operation:
After setting “2. Energy saving ratio” and
“3. Energy saving schedule”, push the
“
” [ F1] button to select “ON”,
then push the [
MENU] button.
To stop the Energy saving operation:
Push the “
” [ F2] button to
select “OFF”, then push the [
MENU] button.
Energy saving ratio
Carry out the setting operation while the indoor unit is stopped. (Turn off the air conditioning unit before starting the
setting operation.)
Energy saving operation
1.Energy saving operation
2.Energy saving ratio
3.Energy saving schedule
ON / OFF
Return
Fix
Energy saving ratio
Energy saving ratio
75%
%
+
%
–
Return
Fix
Set
1
Push the [
∧
] / [
∨
] button to select
“2. Energy saving ratio” on the “Energy saving
operation” screen, then push the “
Set
Set”
[ F2] button.
2
Push the “
%
+
%+” [ F1] / “
%
–
%-”
[ F2] button to set the value.
Æ
The Energy saving ratio can be set within the range
from 50% to 100% by 1%. The lower the value is
set, the higher the power saving effect becomes.
3
Push the [
MENU] button.
Æ
“ Setting” appears on the screen, then the screen
returns to the “Energy saving operation” screen.
NOTE
• Cooling / heating performance may be reduced a little because its power is saved during the Energy saving
operation.
• “
” appears on the display when the Energy saving operation is activated.
• The Energy saving operation cannot be set on the Follower remote control when the dual remote control system
is used.
• The remote control may not be used for setting the Energy saving operation depending on the settings of the
central control remote control or the outdoor unit.
• The Energy saving schedule operation is not available when the clock display is blinking (the clock has not been
adjusted).
– 12 –
23-EN
24-EN
01_OM_1128950202-1_EN.indd 12
01_OM_1128950202-1_EN.indd 12
4/4/2565 BE 11:30
4/4/2565 BE 11:30
Содержание RAV-SM122BTP-UL
Страница 47: ...MEMO MEMO 03_OM_1128950202 1_ES indd 46 03_OM_1128950202 1_ES indd 46 4 4 2565 BE 11 31 4 4 2565 BE 11 31 ...
Страница 48: ...MEMO MEMO 03_OM_1128950202 1_ES indd 47 03_OM_1128950202 1_ES indd 47 4 4 2565 BE 11 31 4 4 2565 BE 11 31 ...
Страница 49: ...03_OM_1128950202 1_ES indd 48 03_OM_1128950202 1_ES indd 48 4 4 2565 BE 11 31 4 4 2565 BE 11 31 ...