1. SPECIFICATIONS
1-1. Outdoor Unit
<Super Digital Inverter>
Model name
Outdoor unit
RAV-
GP561
ATP
*
Power supply
1 phase 220-240V 50Hz
(Power exclusive to outdoor is required.)
Compressor
Type
Hermetic compressor
Motor
(kW)
1.1
Pole
4
Refrigerant
charged
(kg)
1.
35
Refrigerant control
Pulse motor valve
Inter
connecting
pipe
Standard length
(m)
7.5
Min. length
(m)
5
Max. total length
(m)
5
0
Additional refrigerant charge
under long piping connector
2
0g/m
(21m to
5
0m)
Height
difference
Outdoor lower
(m)
30
Outdoor higher
(m)
30
Outer
dimension
Height
(mm)
63
0
Width
(mm)
7
99
Depth
(mm)
29
9
Appearance
Silky shade (Muncel 1Y8.5/0.5)
Total weight
(kg)
4
5
Heat exchanger
Finned tube
Fan unit
Fan
Propeller fan
Standard air flow high
(m
3
/min.)
40
Motor
(W)
43
Connecting
pipe
Gas side
(mm)
12.7
Liquid side
(mm)
6.4
Sound pressure level
Cooling/Heating (dB
·
A)
4
6
/4
8
Sound power level
Cooling/Heating (dB
·
A)
6
3
/6
5
Outside air temperature, Cooling
(°C)
52
to -15
Outside air temperature, Heating
(°C)
15 to -
27
FILE NO. SVM-18041