31
–
Cool mode or dry mode
operation more than 10 mins.
Self-Cleaning
mode operate
30 mins.
Turn off by
remote controller or
timer-off function.
Automatically
turn-off.
Operation time
Item
1
1
. Self-Cleaning
function
Operation flow and applicable data, etc.
• Self-Cleaning diagram
Description
1
2
. Remote
Controller-A or
B selection
1. Purpose
This operation is to operate only
one indoor unit using one remote
controller.
2. Description
When operating one indoor unit in
a situation where two indoor units
have been installed in the same
room or nearby rooms, this
operation prevents the remote
controller signal from being
received simultaneously by both
units, thus preventing both units
from operating.
3. Operation
The indoor unit on which the
remote controller selection has
been set to B receives the signal of
the remote controller also set to B.
(At the factory the remote controller
selection is set to A on all the
indoor units.
There is no A setting display.)
Setting the remote controller
To separate using of remote controller for each indoor
unit in case of 2 air conditioner are installed nearly.
Remote Controller B Setup.
1) Push RESET button on the indoor unit to turn the air
conditioner ON.
2) Point the remote controller at the indoor unit.
3) Push and hold CHK button on the Remote Controller
by the tip of the pencil.
“00” will be shown on the display.
4) Push MODE during pushing CHK.
“B” will show on the display and “00” will disappear
and the air conditioner will turn OFF.
The Remote Controller B is memorized.
Note :
1. Repeat above step to reset Remote Controller to be A.
2. Remote Controller A has not “A” display.
3. Default setting of Remote Controller from factory is A.
Operation display
FCU fan
FCU louver
Timer display
Compressor
CDU fan
ON
ON
rpm is depend on presetting.
OPEN
ON or OFF
depend on presetting of timer function.
ON or OFF
depend on presetting per room temperature.
ON or OFF
depend on presetting per room temperature.
OFF
ON
(450RPM)
OPEN (12.7°)
ON
OFF
OFF
OFF
OFF
CLOSE
ON or OFF
depend on presetting of timer function.
OFF
OFF
AUTO
“B” Display