23
–
+2.5
Ta
[°C]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WB)
*3
*4
*5
L(W6)
Air volume AUTO
L
L+
M
M+
H
W6
(L + M) / 2
W9
(M + H) / 2
WC
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
from M+ and L)
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respectively.
(Table 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate
Description
∗∗∗∗∗
Symbols
UH: Ultra High
H : High
M+:
M : Medium
L+ : Low+
L
: Low
L- : Low–
UL : Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
Fan
speed
level
WF
WE
WD
WC
WB
WA
W9
W8
W7
W6
W5
W4
W3
W2
W1
COOL HEAT
DRY
UH
H
M+
H
M+
M
M
L+
L
L+
L–
L+
L–
UL
L–
UL
UL
SUL
SUL
SUL
RAS-M22SKV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
RAS-M24SKV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
1200
1101
1200
1101
1200
1101
1180
1079
1080
968
1020
902
980
858
850
713
810
669
800
658
760
614
700
547
650
492
500
325
500
325
1250
1156
1250
1156
1250
1156
1230
1134
1130
1034
1070
957
1030
913
900
768
860
669
850
713
810
669
750
603
650
492
500
325
500
325