4
-2. Connecting Cable Connection
Connecting cable
Connecting cable connect to
terminal block (1, 2, 3,
˙
)
Stripping length of the connecting cable
3
Connecting cable
50 mm
45 mm
10 mm
Earth line
about 20 cm
10 mm
Power supply must input at Outdoor Unit Terminal Block.
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected firmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
CAUTION
CAUTION
FILE NO. SVM-18047
POWER INPUT WIRING DIAGRAM
Power input to Outdoor Unit
1 2 3