Item
Operation flow and applicable data,etc
Description
2
2
. Outdoor
control
Quiet
<With Quiet control/Non-select method>
1. Purpose
For the users who concern about noise
of the outdoor unit, this control controls
the max. revolutions of the compressor
to reduce the noise.
2. Description
To reduce noise, [RESET] button of the
indoor unit is kept pushed for 20
seconds.
The number of revolution for the indoor
fan motor and the seup temp value are
kept as they are.
3. Operation
As shown in the table, the maximum
revolution number of indoor unit
compressor can be reduced.
As the maximum number of revolution
of the compressor is restricted, the rise-
up performance at the start time is
weakened.
Select "Con
t
rol" or "No con
t
rol" by keeping
[RESET] button pushed for 20 seconds.
("No control" at shipment from the factory.)
Exchanging from "No control" to "Control" :
Beep sound is heard (Pi, Pi, Pi, Pi, Pi) and
the operation LED 5Hz flashes for 5
seconds.
Exchanging from "Control" to "No control" :
Beep sound is heard.
(Operation LED does not flash.)
<Maximum number of revolution of compressor at normal time and Quiet control time>
RAS-
M
10P
K
VPG-E
RAS-M13PKVPG-E
Quiet controlled
(rps)
COOL
−5°C ~
HEAT
−10 ~ −5°C ~
−10°C ~
Outside temp.
(TO)
Normal time
(rps)
Normal time
(rps)
Quiet controlled
(rps)
2
3
. Operation
mode
se
l
ectable
RAS-M16PKVPG-E
Quiet controlled
(rps)
*
*
*
*
Normal time
(rps)
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Refer
to
the
service manual of outdoor unit
which
combined
.
2
4
. Fireplace
Operation
Fireplace button on remote controller is pressed.
Fireplace 1:
Cancel cold draft prevention control and fan
speed depend on user require base on basic
control.
Fireplace 2:
Cold draft prevention control is active with super
low fan speed (640 rpm).
Keep air circulation during other heat
source applied.
Note:
With Fireplace operation on heating
mode indoor unit always runs and cold
air breezing might be occurred.
Fireplace Operation
8°C
Normal
operation
Fireplace#1
Fireplace#
2
FILE NO. SVM-18047
- 43 -
*
Refer
to
the
service manual of outdoor unit
which combined.