9
-
3
-3. Power Failure During Timer Operation
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Motions
The unit is on standby.
↓
The unit starts to operate.
The
blue
indicator is on.
↓
After approx. three seconds,
The unit beeps three times
and continues to operate.
The
blue
indicator flashes
for 5 seconds.
If the unit is not required to operate at this time, press [RESET]
button once more or use the remote controller to turn it off.
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Motions
The unit is in operation.
The
blue
indicator is on.
↓
The unit stops operating.
The
blue
indicator is turned off.
↓
After approx. three seconds,
The unit beeps three times.
The
blue
indicator flashes
for 5 seconds.
If the unit is required to operate at this time, press [RESET] button
once more or use the remote controller to turn it on.
9
-
3
-2. How to Set the Auto Restart Function
To set Auto Restart Function, proceed as follows:
1. The power supply to the unit must be ON ; The function will not set or reset if the power supply is OFF.
2. Press the [RESET] button located on the front panel of the indoor unit for more than 3 seconds.
3. After 3 seconds, the unit beeps three times and the indicator blinks for 5 seconds.
• When the unit is standby (Not operating)
• When the unit is in operation
•
If Timer operation is set and the power supply shut down accidentally, the previous Timer setting
will be cancelled.
•
Weekly
-
t
imer operation will be not affected by power supply failure, if the remote controller is
located on the position which it can send the command signal to the indoor unit. It is because the remote
controller will send signal
when real clock reach to program setting.
Temporary switch
Temporary switch
FILE NO. SVM-18047