11
EN
ENGL
ISH
Model
4 unit Multi
3 unit Multi
4 unit Multi
RAS-
4M23SAV-E
RAS-
4M23SACV-E
RAS-
3M26GAV-E
RAS-
4M27GAV-E
RAS-
4M27GACV-E
Power source
220–240V ~50Hz
220V ~60Hz
Maximum running current
13.8 A
13.8 A
16.4 A
17.0 A
16.6 A
Installation fuse rating
16 A breaker or fuse
(all types can be used)
20 A breaker or fuse
(all types can be used)
Power cord
H07RN–F or 60245IEC66 (1.5 mm
2
)
H07RN–F or 60245IEC66 (2.5 mm
2
)
Connecting cable
H07RN–F or 60245IEC66 (1.0 mm
2
)
H07RN–F or 60245IEC66 (1.0 mm
2
)
CAUTION
• Incorrect wiring connection may cause electrical parts to burn out.
• Be sure to comply with local regulations/codes when running the wire from outdoor unit to indoor unit. (Size of wire and wiring
method etc.)
• Every wire must be securely connected.
• If incorrect or incomplete wiring is carried out, fire or smoke may result.
• Prepare the power supply for the exclusive use of the air conditioner.
01_OutdoorInstallation_EN.fm Page 11 Friday, March 23, 2007 4:23 PM