– 42 –
FILE NO. SVM-03010(1)
8-2. Installation Diagram of Indoor and Outdoor Units
Shield
pipe
Air filte
r
Hook
Hook
65 mm or more
100 mm or more
1
Installation
plate
Vinyl tape Apply
after carrying out
a drainage test
Saddle
Extension
drain hose
(Option:
RB–821SW)
170 m
m
or more
Extension
drain hose
(Option:
RB–821SW)
Electric
parts
cover
Electric
parts cover
18 Class
Heat pump
60
0 m
m
or
m
or
e
24 Class
18 Class
Cooling only
170 m
m
or more
600 mm or more
600 mm
or more
100 m
m or m
ore
600 mm or more
60
0 m
m
or
m
or
e
Loop the connective cable
(about 100 mm in diameter and 300 – 350 mm long).
Loop the connective cable
(about 100 mm in diameter and 300 – 350 mm long).
For the rear left and left
piping
Insert the cushion between
the indoor unit and wall,
and lift the indoor unit for
better operation.
Wall
The auxiliary piping can
be connected the left, rear
left, rear, right or bottom.
Insulate the refrigerant
pipes separately with
insulation, not together.
6 mm thick heat resisting
polyethylene foam
Left
Rear
left
Right
Rear
Bottom
(Attac
h to th
e fr
ont pan
el) (A
ttac
h to
the air filter)
6
Zeolite filter
7
Purifying filter
5
Filter frame
100 mm
or more
600 mm
or more
100 mm
or more
600 mm
or more
2
Wireless remote control
Before installing the
wireless remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their polarity.
2
Wireless remote control
3
Batteries
Cover
9
Pan head wood screw
4
Remote control holder
Do not allow the drain
hose to get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping
hole sloped
slightly