– 23 –
FILE NO. SVM-03010(1)
5. REFRIGERATION CYCLE DIAGRAM
5-1. RAS-24UKHP-E-1 / RAS-24UAH-E-1
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
*1 : During heating overload, the high temperature limit control operation is included.
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard
0.4
43.0
High
20/–
7/6
Heating
High temperature
0.5 ~ 0.7
52.0 ~ 59.0
Low
27/–
24/18
Low temperature*1
0.3
36.0
High
20/–
–10/–10
Standard
0.4
11.0
High
27/19
35/24
Cooling
High temperature
0.5
12.0
High
32/23
43/26
Low temperature
0.3
1.0
Low
21/15
21/15
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Fan speed
(indoor)
50 Hz
Evaporator
Indoor unit
Cross flow fan
Cooling
Heating
4-way valve
Heating Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PH310X3-4MM
Accumulator
Cooling
Heating
Mark ( ) means check points of Gas Leak
O.D.:15.88 mm
O.D.:6.35 mm
Cooling
Heating
Gas container connection (Reinstall etc.)
Packed valve
(
∅
6.35)
Packed valve
(
∅
15.88)
0.39 m
(Connecting pipe)
∅
15.88
0.49 m
(Connecting pipe)
∅
6.35
T
P
Refrigerant
R22 1.63 kg
Capillary tube
∅
0.8x500
s
Capillary tube
∅
2.4x1400
s