– 19 –
FILE NO. SVM-03010(1)
4-3. Outdoor Unit (RAS-18UAH-E2)
No.
Parts name
Type
Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1
Compressor
PH250X3-4LM
Winding resistance (
Ω
)
C-R
C-S
(at 20
°
C)
2.29
1.22
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2
Fan motor (for outdoor)
KFG6-71SB5P-T3
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
64.4
127.4
3
Running capacitor
451205KQ
AC 450 V, 2
µ
F
(for fan motor)
4
Running capacitor
371456JCR
AC 370 V, 45
µ
F
(for compressor)
5
Solenoid coil
VHV (STF)
AC 220 – 240 V
(for 4-way valve)
6
Thermo sensor
TE / TD
10 k
Ω
at 25
°
C / 50 k
Ω
at 25
°
C
7
Relay
VC20FA
220 – 240 V, 50 Hz, 1P1a
8
Transformer
TT-05
220 – 240 V
9
Microcontroller
TMP47C840N
10
Varistor (R73, R74, R86)
15G471K
470 V
11
Fuse (F01)
MT3
T6.3 A, 250 V
4-4. Indoor Unit (RAS-24UKP-E-1, RAS-24UKPX-1, RAS-24UKP-AR-1, RAS-24UKPX-T-1,
RAS-18UKP-E2, RAS-18UKPX2, RAS-18UKP-AR2, RAS-18UKPX2-T2)
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
ICF-340-30-2
DC 340 V, 30 W
2
Thermo sensor (TA-sensor)
———
10 k
Ω
at 25°C
3
DC-DC transformer (T01)
SWT-58A
DC 390 V, Secondary DC 15 V, 12 V, 7 V
4
Microcontroller
TMP87CM40AN
5
Heat exchanger sensor
———
10 k
Ω
at 25
°
C
(TC-sensor)
6
Line filter (L01)
SS11V-R07190
19 mH, AC 0.7 A
7
Diode (DB01)
D3SBA60
4 A, 600 V
8
Capacitor (C02)
KMH450VNSN120M25S
120
µ
F, 450 V
9
Fuse (F01)
TSCR
T6.3 A, 250 V
10
Relay (for outdoor fan motor,
AJQ1341
Coil DC 12 V, 33 mA, Rated 1 A, AC 250 V
solenoid coil) (RY04)
11
Power supply IC (IC01)
MA8920
5 A, 900 V
12
Varistor (R21, R22)
15G561K
560 V
13
Resistor (R01)
RF-5TK4R7
4.7
Ω
, 5 W
14
Louver motor
MP35EA12
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V