INDOOR UNIT

Installation Place

Remote control

  A place where there are no obstacles such as a curtain that may block the 

signal from the remote control.

  Do not install the remote control in a place exposed to direct sunlight or 

close to a heating source such as a stove.

  Keep the remote control at least 1 m apart from the nearest TV set or 

stereo equipment (This is necessary to prevent image disturbances or 
noise interference).

  The location of the remote control should be determined as shown below.

Cutting a Hole and Mounting

Installation Plate

When the installation plate is directly mounted

on the wall

1. Securely fi t the installation plate onto the wall by screwing it in the upper 

and lower parts to hook up the indoor unit.

2. To mount the installation plate on a concrete wall with anchor bolts, use 

the anchor bolt holes as illustrated in the below fi gure.

3. Install the installation plate horizontally in the wall.

NOTE

  When drilling a wall that contains a metal lath, wire lath or metal plate, be 

sure to use a pipe hole brim ring sold separately.

  A place which provides the spaces around the indoor unit as shown in the 

diagram.

  A place where there are no obstacles near the air inlet and outlet.

  A place which allows easy installation of the piping to the outdoor unit.

  A place which allows the front panel to be opened.

  In case of block, brick, concrete or similar type walls, make 

5 mm holes 

in the wall.

  Insert clip anchors for appropriate mounting screws 

7

.

Installation plate
(Keep horizontal direction)

5 mm hole

Clip anchor
(local parts)

Anchor bolt

Projection
15 mm or less

Cutting a hole

Mounting the installation plate and screw position

CAUTION

  Direct sunlight to the indoor unit’s wireless receiver should be avoided.

  The microprocessor in the indoor unit should not be too close to RF 

noise sources.

  (For details, see the owner’s manual)

1. After determining the pipe hole position, drill the pipe hole (

65 mm) at a 

slight downward slant to the outdoor side.

7

  Mounting screw

 

4 mm x 25 

s

CAUTION

Failure to fi rmly install the unit may result in personal injury and property 
damage if the unit falls.

Remote 
control

Indoor unit

Reception range

(Side view)

(Top view)

Reception range

* : Axial distance

: Pipe hole (

65 mm)

(Side piping)

(Rear piping)

(Bottom piping)

(Unit : mm)

Floor

Wall

Remote control

EN

ES

FR

IT

PT

PL

CZ

RU

CR

HU

TR

NL

GR

SV

FI

NO

DK

RO

BG

EE

LV

SK

SI

DE

4

Содержание RAS-18SAV Series

Страница 1: ...V E RAS 3M18SAV E RAS 3M26GAV E1 RAS 4M23SAV E RAS 4M27GAV E1 RAS 5M34UAV E AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ČESKY PУCСКИЙ HRVATSKI MAGYAR TÜRKÇE NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA ...

Страница 2: ... Łączenie Instalacji Rurowej Czynnika Chłodniczego 7 Usuwanie Powietrza 8 Podłączenie Okablowania 8 Prace Elektryczne 8 INNE 9 Próba Gazoszczelności 9 Ustawianie Przełącznika Wyboru Pilota 9 Ustawienia Przełącznika A B Wyboru Pilota 9 Próba Działania 9 Włączanie Funkcji Automatycznego Wznawiania Pracy Auto Restart 9 PL OBSAH BEZPEČNOSTNÍ OPATŘENÍ 1 SCHÉMA INSTALACE VNITŘNÍ A VENKOVNÍ JEDNOTKY 3 Vo...

Страница 3: ...TE INTERIOARĂ 4 Locul de Instalare 4 Executarea unei Găuri şi Montarea Plăcii de Instalare 4 Cum se Instalează Unitatea Interioară 5 Instalarea Mascată 6 UNITATEA EXTERIOARĂ 7 Locul de Instalare 7 Măsuri de Precauţie privind Instalarea în Regiuni cu ninsori Abundente şi Temperaturi Scăzute 7 Drenarea Apei din Unitatea Exterioară 7 Racordarea Ţevilor de lichid Refrigerent 7 Evacuarea 8 Racordarea C...

Страница 4: ...s of charging port connecting sections on the main unit are different from those for the conventional refrigerant and different size tools are also required For connecting pipes use new and clean piping materials with highpressure withstand capabilities designed for R410A only and ensure that water or dust does not enter Moreover do not use any existing piping as its pressure withstand may be insu...

Страница 5: ... unit is not enough or installation of the unit is improper the unit may fall and result in injury Electrical work must be performed by a qualified electrical engineer in accordance with the code governing such installation work internal wiring regulations and the manual A dedicated circuit and the rated voltage must be used Insufficient power supply or improper installation may cause electrical s...

Страница 6: ...r unit RAS 10 13 18SAV Series 3 Batteries 8 Pan head wood screw 4 Remote control holder Remark Detail of accessory and installation parts can see in the accessory sheet When installing the outdoor unit leave open in at least two of direction A B C and D shown in the figure on the right Do not allow the drain hose to get slack Make sure to run the drain hose sloped downward The auxiliary piping can...

Страница 7: ...pipe hole brim ring sold separately A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened In case of block brick concrete or similar type walls make 5 mm holes in the wall Insert clip...

Страница 8: ... drain hose Do not form the drain hose into a wavy shape Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Drainage 1 Run the drain hose sloped downwards Wiring connection Wiring of the connection cable is necessary to remove the front panel 1 Remove the terminal cover and cord clamp 2 Insert the connecting cable according to the local rule into the pipe ...

Страница 9: ... Floor 670 or more 20 to 30 240 to 250 Floor Wall Side view Unit mm 4 In case of lattice establishment Follow the following figure make sure to keep enough distance between lattice frame and wall Be sure to switch to wall burying mode The lattice should be make of wood Between the air inlet and outlet should be devided with partition board Be sure to establish the open part for RECEIVER The open p...

Страница 10: ...aces A place full of machine oil A saline place such as the coast A place full of sulfide gas A place where high frequency waves are likely to be generated such as from audio equipment welders and medical equipment Strong wind Snow protection plate Snow protection hood At least 50 cm Snow accumulation line Holding frame Front Anchor bolts Install at least 50 cm above the snow accumulation line Do ...

Страница 11: ... valve 6 Open fully the valve stem of the packed valves both gas and liquid sides 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves VACUUMING Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump Do not use the refrigerant in the outdoor unit For details see the manual of the vacuum pump Tightening torque for connection ...

Страница 12: ...ton on the Remote Control by the tip of the pencil 00 will be shown on the display 2 Press during pushing B will show on the display and 00 will disappear and the air conditioner will turn OFF The Remote Control B is memorized Note 1 Repeat above step to reset Remote Control to be A 2 Remote Control A has not A display 3 Default setting of Remote Control from factory is A Unit B setup Press and ho...

Отзывы: