For comfortable sleep, automatically control air
fl
ow and automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note:
The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
COMFORT SLEEP OPERATION
15
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
●
Clean the indoor unit and the remote control with a wet cloth when needed.
●
No benzine, thinner, polishing powder or chemically-treated duster.
Air
fi
lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air
fi
lter.
3. Vacuum or wash and then dry them.
4. Reinstall the air
fi
lters and close the air inlet grille.
MAINTENANCE
17
PRESET OPERATION
AUTO RESTART OPERATION
14
To automatically restart the air conditioner after the power failure (Power of
the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (
sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (
sound but OPERATION lamp does
not blink)
●
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
13
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except air
fl
ow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting.
The
P
mark displays.
3.
Press
: Operate the preset operation.
OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Some minor cracking sound may occur when unit operating. This is
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room Temperature
Cooling
-10°C ~ 46°C
21°C ~ 32°C
Dry
-10°C ~ 46°C
17°C ~ 32°C
The unit does not operate.
Cooling is abnormally low.
●
The power main switch is
turned off.
●
The circuit breaker is
activated to cut off the
power supply.
●
Stoppage of electric
current.
●
ON timer is set.
●
The
fi
lters are blocked with dust.
●
The temperature has been set improperly.
●
The windows or doors are opened.
●
The air inlet or outlet of the outdoor unit
is blocked.
●
The fan speed is too low.
●
The operation mode is FAN or DRY.
●
POWER SELECT FUNCTION is set at
75% or 50%.
TROUBLESHOOTING (CHECK POINT)
REMOTE CONTROL A-B SELECTION
20
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
4.
Press
MODE
during pushing
. “B” will show on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
1
2
TEMPORARY OPERATION
12
In case of the misplaced or discharged remote control
●
Pressing the RESET button, the unit can start or
stop without using the remote control.
●
Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
SELF CLEANING OPERATION
(COOL AND DRY OPERATION ONLY)
16
To protect bad smell caused by the humidity in the indoor unit.
1.
If
the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times within
30 seconds.
18
19
“Pi Pi Pi”
“Pi Pi Pi”
pencil. “00” will be shown on the display ( picture
1
)
Control B is memorized ( picture
2
)