(4) Indoor fan motor automatically starts to rotate by turning on power supply
[For DC fan motor] (For 18K)
<Cause>
The IC is built in the indoor fan motor. Therefore the P.C. board is also mounted to inside of the motor.
If the P.C. board is soldered imperfectly or the IC is defective, the fan motor may automatically rotate by turning
on power supply.
<Inspection procedure>
1.
Remove the front panel. (Remove 2 screws.)
2.
Remove the cover of the fan motor lead wires.
3.
Check DC voltage with CN3
6
connector while the fan motor is rotating.
NOTE :
• Do not disconnect the connector while the fan motor is rotating.
• Use a thin test rod.
Indoor fan starts rotating when power supply is turned on.
(Check output DC voltage of fan motor on P.C. board.)
Measure voltage between 3 (GND : BLACK)
and 5 (V line : YELLOW) of motor connector (CN3
6
)
while indoor fan motor is rotating.
DC 1.0V or more
P.C. board is defective.
6 (Blue)
5 (Yellow)
4 (White)
3 (Black)
2 –
1 (Red)
Motor is defective.
Under DC 1.0V
CN3
6
Yellow
Black
P.C. board
DC
Replace P.C. board.
Replace motor.
FILE NO. SVM-19001
- 95 -
Содержание RAS-18J2AVG-E
Страница 19: ...4 2 Outdoor Unit RAS 05 07 10 13J2AVG E C L C L 280 400 Unit mm FILE NO SVM 19001 19 280 300 ...
Страница 22: ...RAS B16J2KVG E RAS 16J2AVG E FILE NO SVM 19001 22 ...
Страница 23: ...RAS 18J2KVG E RAS 18J2AVG E FILE NO SVM 19001 23 ...
Страница 137: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...