7. REFRIGERANT CYCLE DIAGRAM
7-1. Refrigerant Cycle Diagram
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
INDOOR UNIT
T1
TO
Temp. measurement
TC
TA
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Allowable
height
difference : 1
2
m
Allo
w
ab
le pipe length
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Pulse Modulating
valve at liquid side
TD
4-way valve
Compressor
KSK75D43UEZA
TS
T2
Outdoor heat
exchanger
Temp. measurement
Propeller fan
OUTDOOR UNIT
Muffler
Muffler
Min. : 2m
Chargeless : 15m
Strainer
Max. : 15m
Split capillary
TE
RAS-
B05J2KVG-E / RAS-05J2AVG-E
RAS-B07J2KVG-E / RAS-07J2AVG-E
RAS-B10J2KVG-E / RAS-10J2AVG-E
Strainer
05k and 07
k
Refrigerant amount : 0.
40
kg
10k Refrigerant amount : 0.43kg
FILE NO. SVM-19001
- 25 -
Содержание RAS-18J2AVG-E
Страница 19: ...4 2 Outdoor Unit RAS 05 07 10 13J2AVG E C L C L 280 400 Unit mm FILE NO SVM 19001 19 280 300 ...
Страница 22: ...RAS B16J2KVG E RAS 16J2AVG E FILE NO SVM 19001 22 ...
Страница 23: ...RAS 18J2KVG E RAS 18J2AVG E FILE NO SVM 19001 23 ...
Страница 137: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...