![Toshiba RAS-10UA-E2 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/toshiba/ras-10ua-e2/ras-10ua-e2_service-manual_1135588005.webp)
– 4 –
FILE NO. SVM-03004(1)
MODEL
RAS-10UKHP-E2 / RAS-10UAH-E2
RAS-10UKP-E2 / RAS-10UA-E2
ITEM
Cooling
Heating
Cooling
Capacity
220 V
240 V
220 V
240 V
220 V
240 V
kW
2.70
2.75
3.12
3.15
2.65
2.70
Phase
1
∅
Power source
V
220 – 240
Hz
50
Power consumption
kW
1.00
1.05
0.89
0.91
0.80
0.85
Power factor
%
95
92
94
91
96
94
Running
Indoor
A
0.15
current
Outdoor
A
4.65
4.60
4.15
4.00
3.65
3.60
Starting current
A
19
16
Moisture removal
lit/h
1.2
Noise
Indoor (H/M/L)
dB
39/33/26
Outdoor (220 – 240 V) dB
47
49
47
49
44
45
Refrigerant
Name of refrigerant
R22
Rated amount
kg
0.76
0.68
Refrigerant control
Capillary tube
Gas side size
mm
∅
9.52
Connection type
Flare connection
Liquid side size
mm
∅
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m
10*
1
(One way)
Maximum height
m
5
difference
INDOOR UNIT
RAS-10UKHP-E2
RAS-10UKP-E2
Height
mm
275
Dimensions
Width
mm
790
Depth
mm
208
Net weight
kg
10
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m
3
/h
570
610
630
Air volume
Medium fan
m
3
/h
460
520
490
Low fan
m
3
/h
340
400
370
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT
RAS-10UAH-E2
RAS-10UA-E2
Height
mm
550
Dimensions
Width
mm
780
Depth
mm
270
Net weight
kg
31
30
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/h
2030
2150
2030
2150
1740
1850
Fan motor output
W
18
20
Compressor
Model
PH120T1-4C
2PS146D5AB02
Output
W
750
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range
°
C
15 ~ 43
–10 ~ 24
15 ~ 43