– 12 –
FILE NO. SVM-03004(1)
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13UKHP-E2, RAS-10UKHP-E2)
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
MMF-240-20-4A-1
AC Motor with 135
°
C thermo fuse
2
Thermo sensor (TA-sensor)
———
10k
Ω
at 25
°
C
3
Switching transformer (T01)
SWT-47
4
Microcontroller unit (IC30)
TMP87CM40AN
5
Heat exchanger sensor
———
10k
Ω
at 25
°
C
(TC-sensor)
6
Line filter (L01)
LC*SS11V-06270
27mH, 600mA
7
Bridge rectifier (DB01)
D3SBA60
4A, 60 V
8
Capacitor (C02)
KMH400VSSN47M22S
47
µ
F, 400 V
9
Fuse (F01)
TSCR6.3A
T6.3A, 250VAC
10
Varistor (R21, R22)
15G561K
560 V
11
Resistor (R01)
RF-2TK5R6
5.6
Ω
, 2 W
12
Louver motor
MP24GA
12VDC
13
Relay (Comp., RY01)
DI12D1
Rating 20A/AC250 V, 12VDC
14
Relay (Fan, RY03)
G5N-1A
Rating 3A/AC250 V, 12VDC
15
Relay (Solenoide, RY04)
G5N-1A
Rating 3A/AC250 V, 12VDC
4-2. Outdoor Unit (RAS-13UAH-E2)
No.
Parts name
Type
Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 – 240 V, 50Hz
1
Compressor
PH170T2-4L2
Winding resistance (
Ω
)
C-R
C-S
(at 20
°
C)
2.22
3.04
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50Hz
2
Fan motor (for outdoor)
HF-240-42A
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
176.2
290.5
3
Running capacitor
DS45115CBPQC
AC 450 V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371356CPN
AC 370 V, 35
µ
F
(for compressor)
5
Solenoid coil
VHV-01AJ503C1
AC 220 – 240 V, 50Hz
(for 4-way valve)
6
Overload relay
JMRA99257-9200 U/T : 8.0A (80
°
C), OPEN : 145±5
°
C, CLOSE : 75±11
°
C