![Toshiba RAS-10UA-E2 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/toshiba/ras-10ua-e2/ras-10ua-e2_service-manual_1135588014.webp)
– 13 –
FILE NO. SVM-03004(1)
4-3. Outdoor Unit (RAS-10UAH-E2)
No.
Parts name
Type
Specifications
Output (Rated) 750 W, 2 poles, 1 phase, 220 – 240 V, 50Hz
1
Compressor
PH120T1-4C
Winding resistance (
Ω
)
C-R
C-S
(at 20
°
C)
4.53
8.73
Output (Rated) 30 W, 6 poles, 1 phase, 220 – 240 V, 50Hz
2
Fan motor (for outdoor)
HF-240-20B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
387.3
466.2
3
Running capacitor
DS451155BPQC
AC 450 V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371256CPNB
AC 370 V, 25
µ
F
(for compressor)
5
Solenoid coil
SQ-373
AC 220 – 240 V
(for 4-way valve)
6
Overload relay
JMRA99269-9200 U/T : 6.8A (90
°
C), OPEN : 135±5
°
C, CLOSE : 69±11
°
C
4-4. Indoor Unit (RAS-13UKP-E2, RAS-10UKP-E2, RAS-13UKPX2, RAS-10UKPX2)
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
MMF-240-20-4A-1
AC Motor with 135
°
C thermo fuse
2
Thermo sensor (TA-sensor)
———
10k
Ω
at 25
°
C
3
Switching transformer (T01)
SWT-47
4
Microcontroller unit (IC30)
TMP87CM40AN-2C67
5
Heat exchanger sensor
———
10k
Ω
at 25
°
C
(TC-sensor)
6
Line filter (L01)
LC*SS11V-06270
27mH, 600mA
7
Bridge rectifier (DB01)
D3SBA60
4A, 600 V
8
Capacitor (C02)
KMH400VSSN47M22S
47
µ
F, 400 V
9
Fuse (F01)
TSCR6.3A
T6.3A, 250VAC
10
Varistor (R21, R22)
15G561K
560 V
11
Resistor (R01)
RF-2TK5R6
5.6
Ω
, 2 W
12
Louver motor
MP24GA
12VDC
13
Relay (Comp., RY01)
DI12D1
Rating 20A/AC250 V, 12VDC