– 14 –
FILE NO. SVM-03004(1)
4-7. Outdoor Unit (RAS-10UA-E2)
No.
Parts name
Type
Specifications
Output (Rated) 750 W, 2 poles, 1 phase, 220 – 240 V, 50Hz
1
Compressor
2PSI46D5AB02
Winding resistance (
Ω
)
C-R
C-S
(at 20
°
C)
3.60
4.87
Output (Rated) 20 W, 6 poles, 1 phase, 220 – 240 V, 50Hz
2
Fan motor (for outdoor)
HF-240-20B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
387.3
466.2
3
Running capacitor
DS451155BPQC
AC 450 V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371256CPNB
AC 370 V, 25
µ
F
(for compressor)
5
Overload relay
LPAP960B
U/T : 6.1A (80
°
C), OPEN : 135±5
°
C, CLOSE : 78±11
°
C
4-5. Outdoor Unit (RAS-13UA-E2)
No.
Parts name
Type
Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 – 240 V, 50Hz
1
Compressor
PH160T2-4L2
Winding resistance (
Ω
)
C-R
C-S
(at 20
°
C)
2.43
3.78
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50Hz
2
Fan motor (for outdoor)
HF-240-20B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
387.3
466.2
3
Running capacitor
DS45115CBPQC
AC 450 V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371356CPN
AC 370 V, 35
µ
F
(for compressor)
5
Overload relay
LAAO00A
U/T : 9.0A (80
°
C), OPEN : 135±5
°
C, CLOSE : 75±11
°
C
4-6. Outdoor Unit (RAS-13UAX2)
No.
Parts name
Type
Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 – 240 V, 50Hz
1
Compressor
PH160T2-4LH2
Winding resistance (
Ω
)
C-R
C-S
(at 20°C)
2.43
3.78
Output (Rated) 30 W, 6 poles, 1 phase, 220 – 240 V, 50Hz
2
Fan motor (for outdoor)
HF-240-30B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20°C)
245
388
3
Running capacitor
DS451155BPQC
AC 450 V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371356CPNB
AC 370 V, 35
µ
F
(for compressor)
5
Overload relay
LAAO00A
U/T : 9.0A (80
°
C), OPEN : 135±5
°
C, CLOSE : 75±11
°
C