– 28 –
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
Description
* Symbols
UH
: Ultra High
H
: High
M+
:
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate
+2.5
Ta
[˚C]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WB)
*3
*4
*5
L(W6)
Air volume AUTO
L
L+
M
M+
H
W6
(L + M) / 2
W9
(M + H) / 2
WC
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
from M+ and L)
FILE NO. SVM-1
5004
RAS-077SKV-E7
RAS-107SKV-E7
Cooling
Heating
Cooling
Heating
Fan speed
Air flow rate
(rpm)
(m3/h)
Fan speed
Air flow rate
(rpm)
(m3/h)
Fan speed
Air flow rate
(rpm)
(m3/h)
Fan speed
Air flow rate
(rpm)
(m3/h)
WF
UH
1100
502
1150
534
1200
565
1200
565
WE
UH
H
1100
502
1150
534
1200
565
1200
565
WD
H
M+
UH
1050
471
1050
471
1150
534
1100
502
WC
M+
H
920
390
1000
440
1020
453
1000
440
WB
M
M+
900
378
950
409
950
409
1000
440
WA
M
M
800
316
900
378
900
378
900
378
W9
L+
770
297
820
328
850
347
870
359
W8
L+
L
L+
750
284
700
253
800
316
750
284
W7
L
L-
650
222
660
229
700
253
700
253
W6
L-
L
600
191
600
191
650
222
700
253
W5
UL
UL
L-
580
179
600
179
620
204
650
222
W4
UL
580
179
580
179
620
204
580
179
W3
SUL
SUL/SL-
550
160
550
160
580
179
550
160
W2
SUL
520
141
520
141
520
141
520
141
W1
500
129
500
129
500
129
500
129
RAS-137SKV-E7
Cooling
Heating
Fan speed
Air flow rate
(rpm)
(m3/h)
Fan speed
Air flow rate
(rpm)
(m3/h)
WF
UH
1250
596
1250
596
WE
UH
H
1250
596
1250
596
WD
H
M+
UH
1200
565
1150
534
WC
M+
H
1070
484
1100
502
WB
M
M+
1000
440
1050
471
WA
M
M
950
409
900
278
W9
L+
900
278
850
247
W8
L+
L
L+
850
247
800
316
W7
L
L-
750
284
760
291
W6
L-
L
700
253
700
253
W5
UL
UL
L-
650
222
700
253
W4
UL
620
204
580
179
W3
SUL
SUL/SL-
600
179
550
160
W2
SUL
520
141
520
141
W1
500
129
500
129
Fan speed
level
Fan speed
level
Cool
Heat
Dry
Mode
Mode
Cool
Heat
Dry