6-1. Indoor Unit
6-2. Outdoor Unit
No.
Parts name
Type
Specifications
RPG-240-25A
AC 240V, 2
5W
2 Room temp. sensor (TA-sensor)
( - )
10k
Ω
at 25
°
C
3 Heat exchanger temp. sensor (TC-sensor)
( - )
10k
Ω
at 25°C
4 Louver motor
24BYJ48-HT
P Output (Rated) 1W, 16 poles, DC12V
1
Fan motor (for indoor)
6. SPECIFICATIONS OF ELECTRICAL PARTS
FILE NO. SVM-1
5004
– 18 –
No.
Parts name
Type
Specifications
L = 19mH, 10A
2
Outdoor fan motor
ICF-140-43-4R
DC140V, 43W
3 Suction temp. sensor (TS sensor)
(Inverter attached) 10k
Ω
(25°C)
4 Discharge temp. sensor (TD sensor)
(Inverter attached) 62k
Ω
(20°C)
5 Outside air temp. sensor (TO sensor)
(Inverter attached) 10k
Ω
(25°C)
6 Heat exchanger temp. sensor (TE sensor)
(Inverter attached) 10k
Ω
(25°C)
Reactor
1
20A, AC250V
ASM89D16UEZ
PQ-M01012-000082
SQ-A2522G-000352
3-phases 4-poles
69
0W
DC12V
AC220-240V
Coil for 4-way valve
COIL FOR P.M.V.
Compressor
Terminal block (5P)
7
8
9
10
CH-69-Z-T
Содержание RAS-077SAV-E6
Страница 17: ...FILE NO SVM 15004 4 2 Outdoor Unit C L C L 280 400 16 ...