– 23 –
8-2. Outdoor Unit (Inverter Assembly)
220
–
240V
~
50Hz
MICR
O-COMPUTER BLOCK DIA
GRAM
Driver circuit
of P.M.V.
Heat exchanger
temp.sensor
Suction temp.
sensor
Outdoor air
temp. sensor
Discharge
temp. sensor
Indoor unit
send/receive
circuit
Relay
circuit
Noise
Filter
Converter
(AC
→
DC)
Clock
frequency
10
MHz
High Power
factor Correction
circuit
Input current
sensor
•
PWM synthesis function
•
Input current release control
•
I
PM
over-current detect control
•
Outdoor fan control
•
High power factor correction control
•
Inverter output frequency control
•
A/D converter function
•
P.M.V. control
•
Discharge temp. control
•
4-way valve control
•
Signal communication to indoor unit
P.M.V.
: Pulse Motor Valve
M.C.U. : Micro Control Unit
M.C.U
For INDOOR UNIT
4-way valve
P.M.V.
Inverter
(DC
→
AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC
→
AC)
Outdoor
Fan motor
Compressor
WP-030
(
P
.C.B)
OUTDOOR UNIT
Current
detect
Current
detect
FILE N. SVM-1
5004
220
−
230V
~
60Hz
Содержание RAS-077SAV-E6