User Manual
Page 17
Window Sash
About 1
1/4”
to 1
5/8”
Measure from
the cabinet
edge
Side
Louvers
Window Sill
Sill Angle
Bracket
Fig. 15
Fig. 14A
Right
Left
Locknut
Sill Angle
Bracket
Flathead Bolt
2 Each Required For
Each Support Bracket
1/2” Long Screws
and Locknuts
A. Carefully raise window to expose accordion
panel locking screws. Loosen screws so
accordion panels slide easily.
B. Extend panels to fi ll window opening
completely. Tighten locking screws on top
(Fig. 17).
C. Close window behind top rail.
Fig. 16
1/2” Long
Screws and
Locknuts
Fig. 17
7/16”
Locking
Screw and
Washer
Locking Screw
Check that air conditioner is tilted back
about 1-1/4 in to 1-5/8 in (tilted about 3° to
4° downward to the outside). After proper
installation, condensate should not drain from
the overfl ow drain hole during normal use.
Adjust the slope if otherwise (Fig.15).
NOTICE
5. Secure Accordion Panels
B. Assemble sill angle bracket to support brackets
at the marked position (Fig. 14A). Hand tighten
only so adjustments can be made later.
C. Install support brackets (with sill angle
brackets attached) to correct hole in bottom
of cabinet as shown in Fig. 16.
D. Tighten all 6 bolts securely.
Installa
tion
Instruc
tions