For data storage registers, a boundary error occurs if the specified area (start re register
range) does not exist in either the local or remote ports.
Local port: TermSTS = 0AH, remote port: TermSTS = 8AH
•
A response timeout error (TermSTS = 02H) occurs if the response time from the remote port
exceeds the time specified by the timer counter value.
•
Read protection can be specified for each register type on the local T2N by using the special
coil settings described below. In this case, a memory write protect error (TermSTS = 04H) will
occur.
F
9
8
7
6
5
4
3
2
1
0
SW067
SW C
T
F
D
RW LW W XW/YW
•
When PC link transmission or the UDP socket interface is used, if an application
transmits to a nonexistent remote port, an transmission error (TermSTS = 0BH, detailed
information = 0020H) occurs.
0: Write enabled
1: Write protected
Special registers
Counter registers
Timer registers
PC internal file registers
Expansion file registers (IC card)
Input/output registers
Link registers
Link relay registers
Auxiliary registers
Data registers