Appendix 2 Request Code Table
This table lists the request codes (CMD) used with SEND/RECV instructions sent to the Ethernet
Port. Refer to the section/item indicated in the reference column in the table for detailed
explanations of the request codes.
Table A.2 Instructions (Requests) to the Ethernet Port
Request
Function
Instruction
CMD/Class
Reference
Reset request
Resets the Ethernet Port.
SEND
0011H/(1)
Section 4.3
Parameter setup request Sets up the Ethernet Port parameters.
SEND
0012H/(1)
Section 4.4
Operating mode control
request
Sets the operating mode.
SEND
0013H/(1)
Section 4.5
Remote port verification
request
Verifies the existence of another port on the
network.
SEND
0014H/(1)
Section 7.3
RAS information readout
request
Reads out the Ethernet Port RAS information.
RECV
0015H/(1)
Section 7.6
Time set request
Sets the Ethernet Port internal clock
Time information for event trace
SEND
0018H/(1)
Section 7.5
Register read request
(PC link function)
Reads register data from remote T2N into registers
in the local T2N.
RECV
0021H/(2)
Section 5.4
Register write request
(PC link function)
Writes register data from the local T2N to registers
in remote T2N.
SEND
0021H/(2)
Section 5.3
Remote port loopback
request
Performs a loopback test with another Ethernet
Port on the network.
SEND
000FH/(2)
Section 7.4
UDP open request
Opens a UDP socket.
SEND
0031H/(3)
Section 6.4 (1)
UDP send request
Transmits data from an open UDP socket.
SEND
0032H/(3)
Section 6.4 (2)
UDP receive request
Reads out data received by an open UDP socket.
RECV
0033H/(3)
Section 6.4 (3)
UDP close request
Closes (terminates) an open UDP socket.
SEND
0034H/(3)
Section 6.4 (4)
TCP open request
Opens a TCP socket.
SEND
0035H/(3)
Section 6.4 (5)
TCP send request
Transmits data from an open TCP socket.
SEND
0037H/(3)
Section 6.4 (6)
TCP receive request
Reads out data received by an open TCP socket.
RECV
0038H/(3)
Section 6.4 (7)
TCP close request
Closes (terminates) an open TCP socket.
SEND
0039H/(3)
Section 6.4 (8)
•
The request code (CMD) types (1) to (3) have the following meanings.
Class (1) is module control, (2) is PC link protocol transmission, and (3) is socket interface
transmission.
•
For a single Ethernet Port, it is not possible to request another class (1) CMD while a class
(1) CMD is executing. This is also true for class (2) CMDs. If such a request is issued, the
status will be transmission port busy, and the request will go to the wait state.
•
For a single Ethernet Port, when requesting a class (3) CMD, it is not possible to request
another class (3) command for a socket for which an instruction is executing. If such a request
is issued, the status will be transmission port busy, and the request will go to the wait state.
•
There are eight sockets, and each can independently accept and execute a class (3) instruction.