5-12
October 2000 © TOSHIBA TEC
MR-3011/3012 DESCRIPTION OF OPERATION
(22) Completion of transport operation for back side of next original (original paused at reverse position)
The read motor and reverse motor stop after the reverse sensor is turned OFF to complete transportation of the
back side of the original. The reverse flapper is switched to the exit side by turning OFF the reverse solenoid.
(23) Start of reverse discharge operation of next original
n
Start of feeding operation for next original
n
Original
length sensor OFF
The read motor starts to rotate forward and the reverse motor starts to rotate in reverse. The read roller, exit
roller and reverse roller are rotated to start the reverse discharge of the next original paused at the reverse
position. The reverse motor stops after the reverse sensor has been turned OFF.
(24) Exit sensor OFF
After the exit sensor has been turned OFF, read motor rotates for a certain number of pulses till the next original
has completely discharge.
#Chapter_05.p65
10/5/00, 9:55 AM
12