Hardware Diagnostics
Hardware Diagnostics Program
91
The following items are displayed on the IN PROGRESS screen:
❖
XXXX TEST displays the name of the test being executed.
❖
SUB TEST indicates the subtest number and the step number of the test being
executed.
❖
PASS COUNT shows the pass count of the test.
❖
WRITE DATA indicates the write-data.
❖
READ DATA indicates the read-data.
❖
ADDRESS displays the address of the test being executed.
❖
STATUS provides the status of the test being executed.
If any error occurs during the test, the message "ERROR OCCURRED!" is displayed.
The error name is also displayed next to "ADDRESS".
Details of Test Items and Error Log Information
The following are Test Items and Error log Information items:
❖
01. MEMORY TEST is used to run the memory.
MEMORY TEST (RAM) Error Log
- 01. CONVENTIONAL MEMORY TEST writes data to conventional memory (0 to
640 KB), then reads the new data and compares the result with the test data.
Status
Error name
Meaning
01
PARITY ERROR
Parity error
02
PROTECTED MODE NOT
CHANGE ERROR
Shift to the protected mode failed
FF
DATA COMPARE ERROR
Data comparing error