26
Synchro. Scan Operation
7. 3
The shutter speed can be set by the horizontal scanning period (1H) or by the number of frames.
Setting by 1H
( 1 )
1H/525H ~ 524H/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 μs).
When operating Partial Scanning or binning, the number’s listed below can be used for setting.
Partial scanning/binning OFF
1H/525H ~ 524H/525H
Partial scanning 93fps, E.93fps
1H/340H ~ 339H/340H
Partial scanning 121fps, E.121fps
1H/260H ~ 259H/260H
Partial scanning 126fps, E.126fps
1H/250H ~ 249H/250H
Partial scanning 174fps, E.174fps
1H/181H ~ 180H/181H
Partial scanning 199fps, E.199fps
1H/158H ~ 157H/158H
Partial scanning 250fps, E.250fps
1H/126H ~ 125H/126H
binning
1H/263H ~ 262H/263H
Setting by the frame
( 2 )
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.
(4FRM setting)
n+1
n
RGB data
(video interval image)
(Internal VD)
FVAL
LVAL,
DAVL
Содержание IK-TF5P2