13
Menus
7. 2
s3ELECTTHEMENUTOCHANGETHESETTINGBYREFERRINGTOTHEITEMh5SINGTHE-ENUSv
s7HENTHE;-%.550=;-%.5$/7.=BUTTONSAREPUSHEDTHEh
” on the screen moves up and down.
Move the “
” to the item whose setting you wish to change.
Note:
When performing the mode setting in the menu display while selecting ON in “PART” (Partial Read: refer to
PAGE %42'INh-/$%vANDh"..'v"INNINGREFERTOPAGE THESCREENDISPLAYANDCAMERAOPERATION
switch to normal mode. After closing the MENU, it returns to the previous mode.
SHUTTER (Electronic shutter)
( 1 )
The electronic shutter has four modes; MANU (Manual), SS (Synchro. Scan), E.TRG (External trigger), and AUTO
(Auto Shutter).
Move the “
vTOh-/$%vANDPUSH;$!4!50=;$!4!$/7.=BUTTONTOSELECTTHEDESIREDMODEAMONGh-!.5vh33v
“E.TRG”, and “AUTO”.
MANUAL
:
It is possible to select the exposure time from eleven speed setting; OFF, 1/100s, 1/250s, 1/500s,
1/1000s, 1/2000s, 1/4000s, 1/10000s, 1/25000s, 1/50000s, 1/100000s.
When not using the electronic shutter, select OFF.
Note:
When setting a rapid shutter speed, sensitivity degrades according to the speed.
When a discharging light such as fluorescent lamp, etc. is used for the illumination, the flicker
may be excessive.
SS
:
Shutter speed can be set by the horizontal scanning time (1H) unit or by the number of frames.
E.TRG
:
Exposure is performed and images are output by external trigger. E.TRG includes the five modes
described below. (For details of specifications, refer to the item “7.4 E.TRG (External trigger)”.)
s03.20ULSE3YNC.ON2ESET
4HE CHARGE BEGINS TO ACCUMULATE TO EACH ##$ PIXELS AFTER THE TRIGGER PULSE IS RECEIVED AND
1 frame images are output according to the internal vertical sync signal timing. The exposure/
accumulation time can be set from 0.01 to 16 ms. The trigger signal timing can be set to either the
rising or falling edge.
s0320ULSE3YNC2ESET
4HECHARGEBEGINSTOACCUMULATETOEACH##$PIXELSAFTERTHETRIGGERPULSEISRECEIVED
Upon completion of accumulation the vertical sync signal is reset and 1 frame images are output.
The exposure/accumulation time can be set from 0.01 to 16 ms. The trigger signal timing can be
set to either the rising or falling edge.
s073.20ULSEWIDTHTRIGGER3YNC.ON2ESET
4HECHARGEBEGINSTOACCUMULATETOEACH##$PIXELSAFTERTHETRIGGERPULSEISRECEIVEDAND
frame images are output according to the internal vertical sync signal timing. This is the mode to
set the exposure period by the pulse width of the trigger. The trigger signal polarity can be set to
either the positive or negative polarity.
s07320ULSEWIDTHTRIGGER3YNC2ESET
4HECHARGEBEGINSTOACCUMULATETOEACH##$PIXELSAFTERTHETRIGGERPULSEISRECEIVED
Upon completion of accumulation the vertical sync signal is reset and 1 frame images are output.
This is the mode to set the exposure period by the pulse width of the trigger.
The trigger signal polarity can be set to either the positive or negative polarity.
s222ESETRESTART
Input of an external reset-restart signal permits one screen of information to be output at an arbi-
trary timing.
AUTO
:
Exposure time is automatically controlled to obtain the specified video level.
Содержание IK-TF5P2
Страница 39: ...39 ...